Extending the RS-485 Specification
Some systems require longer distances or higher numbers of nodes than supported
by RS-485. Repeaters are commonly used to overcome these barriers. An RS-485
repeater can be placed in a system to divide the load into multiple segments.
Each “refreshed” signal is capable of driving another 4000 feet (1200 meters) of
cable and an additional 31 RS-485 unit loads. Using an Ethernet network with
switches can also solve this problem. The Veri-Series units represent a single unit
load to the transmission line.
Figure 14: Wiring Diagram for RS-232/RS-485 Converter
Wiegand Ground
Wiegand Out Data1
Wiegand Out Data0
Power
Supply
+12 VDC
Ground
Pigtail
Door
Controller
Data 0
Data 1
Common
Earth
Ground
To
Computer
RS-232
TD(A)
TD(B)
RD(A)
RD(B)
+12VDC
GND
RS-485 (-)
RS-485 (+)
Connect to
Earth
Ground
Twisted Pair.
Use Cat5 rated cable
Figure 13: Network Configuration