User's Manual
POWER DISTRIBUTION & READER HOOKUP
Part # 430-00186-00 ©Copyright 2007, Bioscrypt Inc.
PIV-Station Installation Guide All rights reserved.
24
The readers are connected to other components of an integrated system through the rear of the reader. This is
made up of the connections described in Table 5.
Pin Group Label Signal Description
8-Pin Connector:
1 TX(+) Transmit +
2 TX(-) Transmit -
3 RX(+) Receive +
4 RX(-) Receive -
5
RS-485
GND RS-485 Signal Ground
6 GND RS-232 Signal Ground
7 TX Transmit
8
RS-232
RX Receive
3-Pin Connector:
1 +(POS) 12.5 – 24 VDC +
2 -(NEG) 12.5 – 24 VDC -
3
Power/Ground
EGND Earth Ground
12-Pin Connector:
1 IN 0 Data 0 In
2 IN 1 Data 1 In
3 OUT 0 Data 0 Out
4 OUT 1 Data 1 Out
5 LED IN LED In
6 LED OUT LED Out
7
Wiegand
GND Wiegand Ground
8 IN 0 TTL Data 0 In
9
TTL (IN)
IN 1 TTL Data 1 In
10 Out 0H TTL Data 0 Out
11 OUT 1L TTL Data 1 Out
12
TTL (OUT)
GND TTL Ground
Table 5: PIV-Station Weidmuller Connections
Comment [D4]: Check these.