User's Manual
EARTH GROUND
Part # 430-00186-00 ©Copyright 2007, Bioscrypt Inc.
PIV-Station Installation Guide All rights reserved.
4
2 Earth Ground
It is extremely critical for proper operation of the Reader that the earth ground be properly connected to avoid
damage by ESD. Connect the terminal labeled EGND to earth ground. This wire should not be connected to
the neutral, the cable shield, or any other wire except earth ground. See Figure 1 (PIV-Station Contactless
CHUID Reader shown) below.
• EARTH GROUND: A low impedance path to earth for the purpose of discharging lightning,
static, and radiated energy, and to maintain the main service entrance at earth potential. Consult local
codes for guidelines.
• ESD: Electrostatic Discharge (static electricity). The effects of a static discharge can degrade
or destroy semiconductor junctions for an electronic device.
Figure 1: Earth Ground Connections
Earth Ground
To protect reader from ESD
EGND connector on unit back
Power (+)
Power Ground (-)
Comment [D1]: Need new picture?