User Manual
Table Of Contents
- Cover
- 1 Product Description
- 2 General Safety Instructions
- 3 Implantation
- Implantation Procedure
- Having parts ready
- Keeping an external defibrillator ready
- Unpacking the device
- Checking parts
- Implantation site
- Preventing leakage currents
- Preventing unintentional shock delivery
- Avoiding damage to the header
- Preventing short circuits in the header
- Ensure that connector ports are clean
- Overview: Implanting
- Connecting the device
- Keeping distance between leads
- Applying the programming head
- Establishing RF telemetry
- Activating ICD therapy
- Precautionary Measures while Programming
- Performing standard tests and monitoring the patient
- Cancelling telemetry
- Avoiding critical parameter settings
- Avoiding risks in the case of exclusive LV pacing
- Monitoring the patient when setting asynchronous modes
- Complying with the morphology criteria
- Setting sensing
- Preventing device-induced complications
- Preventing conduction of atrial tachycardia
- Avoiding AV crosstalk
- Observing the shock impedance limit
- Preventing recurrence after therapy shock
- Phrenic nerve stimulation that cannot be terminated
- Note the reduced pulse amplitude due to a battery voltage drop
- Observe when inducing short-term cardiac arrest
- Checking the settings of the DX lead
- Checking for electrodes suitable for the shock path
- Recognizing lead failure
- Considering power consumption and service time
- Magnet Response
- Follow-up
- Patient Information
- Replacement Indications
- Explantation and Device Replacement
- Implantation Procedure
- 4 Parameters
- Bradycardia / CRT
- General ICD therapy
- Timing: Basic rate day/night and rate hystereses
- Timing: AV delay
- Timing: Post-shock pacing
- Timing: Upper rate
- Timing: Mode switching
- Timing: Ventricular pacing suppression
- Timing: Ventricular pacing
- Timing: Ventricular multi pole pacing
- Timing: Refractory periods and blanking periods
- Timing: PMT protection
- Timing: Rate adaptation via accelerometer
- Timing: Rate adaptation via CLS
- Pacing: Pulse amplitude and pulse width
- Pacing: Atrial capture control
- Pacing: Ventricular capture control
- Lead configuration LV on IS-1 connection
- Lead configuration LV on IS4 connection
- MRI program
- Tachycardia
- Sensing
- Diagnostics
- Home Monitoring
- Bradycardia / CRT
- 5 Technical Data
6
BIOTRONIK Home Monitoring
®
In addition to effective pacing therapy, BIOTRONIK provides a complete therapy
management system:
•
With Home Monitoring, diagnostic and therapeutic information as well as technical
data are automatically sent to a stationary or mobile transmitter via an antenna in
the device header. The data are encrypted and sent from the transmitter to the
BIOTRONIK Service Center via the cellular phone network.
•
The received data are deciphered and evaluated. Each physician can set the criteria
for evaluation to be used for each patient and can configure the time of notification
via e-mail, SMS or fax.
•
A clear overview of the results of this analysis is displayed for the attending physi-
cians on the protected Internet platform Home Monitoring Service Center (HMSC).
•
Data transmission from the device is performed with a daily device message.
•
Device messages which indicate special events in the heart or in the device are
forwarded immediately.
•
A test message can be initiated at any time using the programmer to immediately
check the Home Monitoring function.
Intica order numbers
Not all device types are available in every country:
Package contents
The storage package includes the following:
•
Sterile packaging with device
•
Serial number label
•
Patient ID card
•
Warranty booklet
Note:
The technical manual pertaining to the device is either included in hard copy
form in the storage package or in digital form on the internet.
The sterile container includes the following:
•
Device, blind plugs (if applicable)
•
Screwdriver
Intica 5 ProMRI
DF-1/IS-1 DF4/IS-1 DF-1/IS4/IS-1 DF4/IS4/IS-1
VR-T 404689 404690 — —
VR-T DX 404688 — — —
DR-T 404686 404687 — —
HF-T 404683 404684 — —
HF-T QP — — 406932 404685
Intica 7 ProMRI
DF-1/IS-1 DF4/IS-1 DF-1/IS4/IS-1 DF4/IS4/IS-1
VR-T 404634 404635 — —
VR-T DX 404633 — — —
DR-T 404631 404632 — —
HF-T 404627 404628 — —
HF-T QP — — 404629 404630