User's Manual

23
Technical dataFunction overview (remote control unit)
Section Function Key combination Levels
Motion detector
4.1 Output signal active/passive/OFF
+ + …
312F
*active passive
OFF
3
21
4.2 Comfort functions
+ …
51C
see page 24
4.3 Direction recognition
+ + …
218F
*ON
OFF
2
1
4.4 Field size (sensitivity)
+ …
91D
, , small
, , * medium
, , large
987
654
321
4.5 Additional output fall-delay time
+ + …
611F
0.2 s, short 0.5 s, short
*1.0 s, medium 2.0 s, medium
3.0 s, long 5.0 s, long
65
43
21
4.6 Cross-traffic optimisation
+ + …
915F
*OFF
,low
, , medium
, , high
987
654
32
1
4.7 Slow Motion Detection (SMD)
+ + …
913F
OFF, no SMD
* short, decreasing
long, decreasing
short, constant
long, constant
98
76
54
32
1
4.8 Field size SMD
+ + …
917F
, , small
,*, medium
, , large
987
654
321
4.9 Digital filter functions
+ + …
416F
interf. supp. filter ON
*OFF
door filter ON
interf. supp. filter + door filter ON
4
3
2
1
Presence detector
10.1 Output signal active/passive/OFF
+ + …
312E
*aktive passive
OFF
3
21
10.2 Test input (polarity)
+ + …
213E
* high active
low active
2
1
10.3 Test input delay
(dependent on test frequency)
specification ± 10%
Pulse-break ratio 1:1
at 10 Hz at 50 Hz at 100 Hz
+ +
*
14E
4 ms 3.7 ms 3 ms
+ +
24E
6 ms 5 ms 4 ms
+ +
34E
8 ms 6 ms 4.6 ms
+ +
44E
10 ms 7 ms
+ +
54E
12 ms 8 ms
+ +
64E
14 ms 9 ms
+ +
74E
16 ms
+ +
84E
18 ms
+ +
94E
20 ms
10.4 Manual teach-in of the background
+
3A
Teach-in of background
10.5 Teach-in time + + …
916E
*1min, medium 8 s, short
15 s, short 30 s, short
2 min, medium
5 min, medium
15 min, long 30 min, long
Infinite
9
87
65
43
21
10.6
Teach-in mode
+ + …
215E
fixed
* adaptive
2
1
10.7 Width of detection area
+ …
91B
see section 10.7
10.8 Sensitivity
+ + …
411E
high 1
* high 2
low 1
low 2
43
21
10.9
Deactivate presence detector
temporarily
+ +
+
2A
21A
+ deativate
*
activate (automatic mode)
2
21
10.10 Depth of detection area
+ + …
317E
see section 10.10
General functions
20.2
21.3
Configuration mode
+ +
+ +«Code»+
C9C
31A
deactivate configuration mode
activate configuration mode
14
Manual detection (15 min.)
+ +
+
2A
11A
+
activate manual detection
*
automatic mode
2
11
15 Combined outputs
+ + …
219E
**
ON
*OFF
2
1
16 (21) Access code
++ +
CXXXX9C
1111*–9998 save/switch on
9999 delete
17 Reset
+
9A
Factory default settings
18 Self-test
+ + …
414A
*All self-tests ON
Floor self-test OFF, module self-test ON
Floor self-test ON, module self-test OFF
All self-tests OFF
4
3
2
1