User's Manual

20.5 Connection set-up with address selection
1.
Cover the Reglobeam’s infrared interface
with your hand.
2.
Press
flashes
3.
Uncover the IR interface and press one
of the keys ...
(address of the desired sensor)
and also one of keys … lights up if the
connection has been successfully established.
If and one of the keys to light up,
but no further settings are possible,
then configuration mode is not activated.
Activate configuration mode
(section 20.2)
GG
If continues to flash, no connection
could be made.
Check whether the correct address
has been set or selected.
Hold the remote control unit closer
to the sensor and aim it directly at it.
Check the batteries in the Reglobeam.
If no keys light up on the Reglobeam,
replace the batteries.
Note
The connection to the choosen sensor is set-up
as long as the connection has to be set-up newly
by pressing .
G
G
1 4
1 4
G
G
1 4
The code can only be saved if the sensor is already in
configuration mode (see section 20.2). The unit is protected
as soon as the code has been saved (configuration mode is
deactivated).
1.
Press the start key
and one of the keys … light up
2.
Press and then
and light up
Access code” function is switched off
(no code is saved)
3.
Enter four-digit code
(any number from 1111 to 9998 can be chosen)
4.
Press
and light up
Access code” function is switched on
(code is saved)
Configuration mode is deactivated
(unit is protected)
G
G 1 4
C
C
9
C
C
2
1
The code may only be cleared when the sensor is in
configuration mode (see section 20.2).
1.
Press the start key
and one the keys … light up
2.
Press and then
and light up
Access code” function is switched on
3.
Press our times and then press
and light up
Access code” function is switched off
(code is cleared)
G
C 1
C 9
C 2
9 C
G
1 4
Jupiter/Jupiter SE/Jupiter Presence can be protected with a four-digit access code against unwanted manipulation by third parties.
This code enables configuration mode to be reactivated at any time by remote control in order to make settings.
This Access code” function is switched on by default (code 1111).
Switching on the “access code” function
(saving the code)
Switching off the “access code function
(clearing the code)
21 Access code
21.1
21.2
37
Configuration mode can only be activated by remote control
unit if a code has been saved previously (see section 21.1).
1.
Press the start key
and one of the keys … light up
2.
Press and then
and light up
Access code” function is switched on
3.
Enter your four-digit code
4.
Press
and light up
Configuration mode is activated
Sensor is ready to be programmed
If and light up, then the code entered
is wrong
Start again at step 1.
G
1 4
C
C
9
C
G
C
1
1
C 2
Activating configuration mode21.3
X
Y
Control key
Control key
Important: all unit parameters are set to
factory default.
Press the control keys and simultaneously for
8 seconds. Both LEDs light up briefly every two seconds.
Unit is reset to its default settings
Access code” function is switched off (code is cleared)
A new initialisation and teach-in phase begins
(see chapter 3)
YX
Switching off the “access code function (clea-
ring the code) without the remote control unit
21.4
Control keys