User's Manual

39
frequency = 24.05 24.25 GHz
max. switching voltage 48 V AC/DC
max. switching current 0.5 A AC / 1.0ADC
max. switching capacity 60 VA /30 W
output combinably with output of presence
detector
max. switching voltage 48 V AC/DC
max. switching current 0.5 A AC / 1.0ADC
max. switching capacity 60 VA /30 W
output combinably with output of presence
detector
external power supply 1236 V DC
max. output current 50 mA
max. residual voltage 2 V
output frequency 100 Hz; duty-cycle 1:1
at a divergence of max. 10%
output combinably with output of presence
detector
output voltage ) 10 V DC
output current * 10 mA at 3.2 V DC
output combinably with output of presence
detector
Technology
Outputs
Doppler radar with planar module
Jupiter
relay output: 1 contact potential free
active/passive switchable
fall time adjustable in 6 levels
Jupiter SE /R
relay output: 2 contacts potential free
contacts are opened on detection
or in the case of an intern error
fall time adjustable in 6 levels
Jupiter SE /F
frequency output
rectangle NPN-PNP
push-pull/power stage
fall time adjustable in 6 levels
Jupiter SE /V
voltage output
for direct connection of
optoelectronic coupler
fall time adjustable in 6 levels
Motion detector
type of light: infrared, wavelength = 870nm
max. 600 ms
max. 600 ms
max. output voltage 40 V DC
max. output current 100 mA
max. residual voltage 1 V
at max. output current
output combinably with output of motion
detector
max. input current 10 mA
max. test frequency 150 Hz
at duty-cycle 1:1
Technology
Response time
Fall time
Output
Test input
active infrared (AIR)
typ. 400 ms
typ. 400 ms
transistor ouput
configurable as NPN or PNP (jumper)
compatible to light beam series
PLP 6/5 and PLP 8/5
short circuit proof
4 variants possible
compatible to light beam series
PLP 6/5 and PLP 8/5
Presence detector
additional to Jupiter SE /R: 2 x 0.14 mm
2
(AWG 26), length 3 m (9.8') with plug
at 24 V DC and 20° C (18° F)
at pulse width > 20 µs
color black; optic surface: PC
W x H x D
– in acc. with EMC directive 89/336/EEC
– EC type-examination certificate in acc. with
machinery directive 98/37/EC, annex 1
– in acc. with R&TTE directive 1999/5/EC
FCC / IC
min./max.
mounting height
Connection cable
Operating voltage
Operating current
Current at make
Material
Dimensions (housing)
Protection class
Operating temperature
Humidity
Electomagnetic
compatibility
Approvals
1.5 m / 3.0 m (4.9'/9.8')
8 x 0.14 mm
2
(AWG 26),
length 3 m (9.8') with plug
1236 V DC
max. 200 mA
max. 1 A
cover: ABS; base plate: ABS/ PC
250 x 62 x 47 mm (9.84"x 2.44"x 1.85")
suitable for application in accordance with IP54
–20° C to 60° C (-4° F to 140° F)
0% to 90% relative, not condensing
– Immunity in acc. with: EN 61000-6-1 and
EN 61000-6-2
– Emission in acc. with: EN 61000-6-3 and
EN 61000-6-4
– DIN 18650, edition 2005
– EN 12978, edition 2003
– EN 61508, edition 2001
– EN 954-1, edition 1996
– EN 61496-2, edition 2002
– Recommendation automatic
sliding doors in emergency routes,
edition 1997
(Jupiter SE only)
General informations
Technical data