User's Manual

TX RX Systems Inc. Manual 7-9485-1.9.1 10/26/17 Page 19
is illuminated the feature is on and when it is dark
the feature is off. The Carrier Squelch status indi-
cator will be green if the channel is squelched. The
Carrier Squelch status indicator will stay dark if
there is no squelching even if the Carrier Squelch
radio button is set to enabled. A test signal can be
generated for any channel within the system or
every channel simultaneously.
The output power box displays the output power for
the channel module. This value should be close but
not necessarily exactly the same as the “Desired
Output Level” discussed earlier. The box showing
output power is only displayed if the filter is giving
an output power. If the filter is not enabled or there
is no signal present then there would be no value
to display.
LINK TAB
The link page is divided into three functional areas
including a row of command buttons running down
the left side of the screen, a link and a settings
area in the middle of the screen, and finally a sta-
tus area on the right side of the screen as shown in
Figure 13. The link page is designed to interact
with one branch of a module at a time. The branch
that is selected for interaction is determined by the
Link box on the upper left of the screen. To change
the branch that you are going to interact with click
on the arrow to display the full drop down box.
Scroll down the list until the desired branch is high-
lighted and click on it. The data displayed in the link
area of the display screen will now be for the
selected branch.
Command Buttons
Clicking on a command button (located on the
extreme left-hand side of the page) performs the
associated task immediately. The Submit and
Reload buttons in the bottom left corner allow any
changes you make to the display/interface boxes to
be downloaded to the booster. The Submit and
Reload buttons act like a trigger sending any
changes you made in the interface boxes to the
Figure 12: The design filter interactive display screen.