ID Name Class Severity Unit
46 Temperature Alarm 0x0010 Error FOR
Description
Temperature is above 90° C (194° F) for the FOR. High power units may start
reducing their output power to protect itself from overheating.
NOC Actions N/A
Field Actions
Check the reason for overheating. Arrange for ventilation if insufficien
t. For
outdoor units, deploy the sun shield that is available for the Bird remote unit.
ID Name Class Severity Unit
51 RF Voltage low 0x0010 Error FOR
Description The measured RF voltage is below threshold.
NOC Actions Dispatch field tech to replace unit.
Field Actions Replace unit.
ID Name Class Severity Unit
52 RF Voltage high 0x0010 Error FOR
Description The measured RF voltage is above threshold.
NOC Actions Dispatch field tech to replace unit.
Field Actions Replace unit.
ID Name Class Severity Unit
53 Analog voltage 0x0010 Error FOR
Description
The 3 V supply voltage is not within the specified range. This is a hardware
fault.
NOC Actions Dispatch field tech to replace unit.
Field Actions Replace unit.
ID Name Class Severity Unit
54 Negative Voltage 0x0010 Error FOR
Description The measured negative voltage is above threshold. This is a hardware fault.
NOC Actions
Check the output power of the unit if it is still functioning. Dispatch field tech to
replace unit.
Field Actions Replace unit.