ID Name Class Severity Unit
53 Analog voltage 0x0030 Error BIU
Description 3 V supply for analog parts are not within the acceptable range.
NOC Actions Dispatch field tech to replace card.
Field Actions Replace card.
ID Name Class Severity Unit
54 High BTS signal 0x0030 Error BIU
Description
The received RF signal from the BTS is above the alarm threshold. The alarm
threshold can be set at commissioning time.
NOC Actions
Check with engineers and adjust by remote to proper levels in BIU card. If input
is too high for the card to handle, dispatch field tech to insert attenuator
between BTS and BIU card.
Field Actions
Readjust or attenuate the BTS signal properly. Readjust the DL and UL for the
sector when done with the attenuation.
ID Name Class Severity Unit
55 High BTS signal 0x0030 Config BIU
Description
Measured output from the BIU is above a certain threshold. Alarm can be
configured on, off, level and criticality by the tech.
NOC Actions
Check with engineers and adjust by remote to proper levels in BIU card. If input
is too high for the card to handle, dispatch field tech to insert attenuator
between BTS and BIU card.
Field Actions
Readjust or attenuate the BTS signal properly. Readjust the DL and UL for the
sector when done with the attenuation.
Troubleshooting
136
Medium Power Amplifier (PA) Alarms
ID Name Class Severity Unit
1 AD Converter fault 0x0100/0x0101 Error PA
Description
The AD converter on the board is malfunctioning. This is a hardware failure.
There is a risk the RF output is not working.
NOC Actions Dispatch field tech to replace the unit as soon as possible.
Field Actions Replace failed unit.