Operation Manual

Table Of Contents
ID Name Class Severity Unit
5 IO port 0x0103 Warning MPI
Description The IO port has failed. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
6 5V Analog 0x0103 Warning MPI
Description The 5 V analog voltage has failed. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
7 Table missing 0x0103 Warning MPI
Description Configuration or calibration database error. This is a software error.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
11 Temperature alarm 0x0103 Error MPI
Description The temperature in the unit is too high.
NOC Actions Dispatch field tech to check environmental conditions.
Field Actions
Check ventilation and arrange for good air flow. If outdoor unit mount sun
screen.
ID Name Class Severity Unit
11 Temperature alarm 0x0103 Warning MPI
Description The temperature in the unit is too high.
NOC Actions Dispatch field tech to check environmental conditions.
Field Actions
Check ventilation and arrange for good air flow. If outdoor unit mount sun
screen.
Fiber Distributed Antenna System (Fiber DAS)