Operation Manual
Table Of Contents
- Safety Precautions
- About This Manual
- Table of Contents
- Chapter 1 Introduction
- Chapter 2 System Description
- Chapter 3 Installation guidelines
- Chapter 4 DAS Software Configuration
- Chapter 5 Commissioning
- Chapter 6 RF Commissioning
- Chapter 7 Troubleshooting
- Alarms
- Base Station Gateway (BGW) Alarms
- Fiber Optic Remote (FOR) Alarms
- Remote Unit (RU) Alarms
- Fiber optic Interface (FOI) Alarms
- Base Station Interface (BIU) Alarms
- Medium Power Amplifier (PA) Alarms
- Variable Gain Amplifier (VGA) Alarms
- Analog Pre-distortion (APD) Amplifier Alarms
- Multi-carrier Power Amplifier Interface (MPI) alarms
- Alarms
- Chapter 8 Model Identification
ID Name Class Severity Unit
12 Temperature alarm low 0x0103 Warning MPI
Description The unit is very cold.
NOC Actions
Generally this happens if it has been powered down in a cold loca
tion for a long
time. Unit will warm up and come back to operation when it has heated itself
for a while. Wait an hour and check temperature.
Field Actions
Generally this happens if it has been powered down in a cold loca
tion for a long
time. Unit will warm up and come back to operation when it has heated itself
for a while. Wait an hour and check temperature.
ID Name Class Severity Unit
21 Board supply voltage high 0x0103 Error MPI
Description The supplied voltage is out of bounds. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
22 Board supply voltage low 0x0103 Error MPI
Description The supplied voltage is out of bounds. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
101 supply voltage high 0x0103 Error MPI
Description PA supplied voltage is out of bounds. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
ID Name Class Severity Unit
102 supply voltage low 0x0103 Warning MPI
Description PA supplied voltage is out of bounds. This is a hardware fault.
NOC Actions Dispatch field tech to change the remote unit.
Field Actions Replace remote unit.
Troubleshooting
150










