Operation Manual
Table Of Contents
- Safety Precautions
- About This Manual
- Table of Contents
- Chapter 1 Introduction
- Chapter 2 System Description
- Chapter 3 Installation guidelines
- Chapter 4 DAS Software Configuration
- Chapter 5 Commissioning
- Chapter 6 RF Commissioning
- Chapter 7 Troubleshooting
- Alarms
- Base Station Gateway (BGW) Alarms
- Fiber Optic Remote (FOR) Alarms
- Remote Unit (RU) Alarms
- Fiber optic Interface (FOI) Alarms
- Base Station Interface (BIU) Alarms
- Medium Power Amplifier (PA) Alarms
- Variable Gain Amplifier (VGA) Alarms
- Analog Pre-distortion (APD) Amplifier Alarms
- Multi-carrier Power Amplifier Interface (MPI) alarms
- Alarms
- Chapter 8 Model Identification
System Description
18
Figure 16 DOI301/302
FOI
ALM
ON
UL OUT 1
OPTO IN/OUT
TP DL
RES
TP UL
DL IN 1
DL IN 2
UL OUT 2
DOI302
With WDM
DOI301
Without WDM
FOI
ALM
ON
UL OUT 1
OPTO OUT
OPTO IN
TP DL
RES
TP UL
DL IN 1
DL IN 2
UL OUT 2
Interfaces
Item Description
OPTO IN/OUT
SC-APC connection for the optical fiber.
DOI302 module with built in WDM has a single connector (combined RX/TX).
DOI301 module without WDM has two connectors, one for TX and one for RX.
UL OUT 1/2 Uplink ports (QMA) to the ICU.
DL IN 1/2 Downlink ports (QMA) to the ICU.
TP UL/DL Test ports (QMA) used to check the signal levels or noise in the system.
The two LEDs on the unit provide FOI status as shown in
Table 11
.
Table 11
State ON LED ALARM LED Note
Booting 2 Hz Off Normal boot
Booting standalone mode 2 Hz 2 Hz Not attached to rack
Booting read of MAC address failed 2 Hz On Error
Starting 0,1 Hz 90% 0,1 Hz 90% Kernel startup
Operation 0,5 Hz 10% Off Normal operation
Operation 0,5 Hz 10% 1 Hz 10% Minor alarm state
Operation 0,5 Hz 10% 2 Hz 25% Major alarm state
Operation 0,5 Hz 10% On Critical alarm state
FOI LED Indicators
Table 12 DOI302 Specifications
Parameter Value
Maximum fiber loss from MU to RU, Optical, 15 dBo
Optical output power, Calibrated 3 000 μW
Maximum number of RU supported on single fiber 4
Input RF power recommended, Composite -50 to -35 dBm
Power consumption < 15 W
Operational Temperature range 0 to 45 °C (32 to 133 °F)
Module Width 1 card slot
Optical connector type SC-APC
RF connector type QMA Female