Operation Manual
Table Of Contents
- Safety Precautions
- About This Manual
- Table of Contents
- Chapter 1 Introduction
- Chapter 2 System Description
- Chapter 3 Installation guidelines
- Chapter 4 DAS Software Configuration
- Chapter 5 Commissioning
- Chapter 6 RF Commissioning
- Chapter 7 Troubleshooting
- Alarms
- Base Station Gateway (BGW) Alarms
- Fiber Optic Remote (FOR) Alarms
- Remote Unit (RU) Alarms
- Fiber optic Interface (FOI) Alarms
- Base Station Interface (BIU) Alarms
- Medium Power Amplifier (PA) Alarms
- Variable Gain Amplifier (VGA) Alarms
- Analog Pre-distortion (APD) Amplifier Alarms
- Multi-carrier Power Amplifier Interface (MPI) alarms
- Alarms
- Chapter 8 Model Identification
System Description
24
FCC/IC standard
Bird’s Distributed Radio head is a high performing wideband radio head equipped with a linear power amplifier
supporting all modulations. The light weight, convection cooled IP65 chassis secures the performance in almost any
environment.
Table 22 General Specifications
Noise Figure, Typical 3 dB
Delay excluding optical fiber < 0.5 μs
Power Supply
Standard
Optional
85 – 264 VAC
-32 to -100 VDC
Operating Temperature -25 to 55 °C (-13 to 131 °F)
Casing IP65
Table 23 Specifications DDR100 (Single Band) & DDR200 (Dual band)
Power Consumption, max, DDR 100 (200) 90 (180) W
Dimensions, W x D x H
11.8 x 5.1 x 27.6 in.
30 x 13 x 70 cm
Weight < 34 lbs (15.2 kg)
Table 24 Specifications DDR300 (Triple Band) & DDR400 (Quad Band)
Power Consumption, max, DDR 300 (400) 270 (360) W
Dimensions, W x D x H
11.8 x 8.7 x 27.6 in.
30 x 22 x 70 cm
Weight < 60 lbs (27.2 kg)
Cellular Products
Table 25 Available Products, FCC/IC
System UL Frequency MHz DL Frequency MHz
Pout, DL,
dBm (Composite)
Standard
LTE LB 698 - 716 728 - 746 33 FCC/IC
LTE UB
776 – 787
†
† Sub-bands available
746 -757† 33 FCC/IC
iDEN 806 - 824 851 - 869 33 FCC/IC
Cellular 824 - 849 869 - 894 33 FCC/IC
PCS1900 1850 - 1915 1930 - 1995 33 FCC/IC
AWS 1710 - 1780 2110 - 2180 33 FCC/IC
WCS 2300 2305 - 2315 2350 - 2360 33 FCC/IC
IMT-E 2500 - 2570 2620 - 2690 33 FCC/IC
Class B Industrial Booster — This equipment is a Class B Industrial Booster and is restricted to installation as
an In-building Distributed Antenna System (DAS).
FCC RF Exposure — This equipment complies with the FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with the following minimum distances
between the radiator and your body:
LTE 700 MHz (DDR700) 204.7 cm
iDEN 800MHz (DDR850) 173.0 cm
PCS 1900MHz (DDR1900) 142.9 cm
AWS-1 2100MHz (DDR2100) 134.9 cm
AWS-3 2155MHz (DDRAWS3) 97.7 cm
WCS 2300 MHz 97.7 cm
If system will operate on multiple bands, the separation distance required shall be equal to, or greater than, the
band with the largest separation distance.