FCC RF Exposure — This equipment complies with the FCC RF radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with the following minimum distances
between the radiator and your body.
VHF public safety band 69.1 cm - This distance must be maintained when a 10.5dBi antenna is used.
Low Band UHF public safety band 36.2 cm - This distance must be maintained when a 3.5dBi antenna is used.
UHF public safety band 20.0 cm
700MHz public safety band 36.2 cm - This distance must be maintained when a 5.5dBi antenna is used.
800MHz public safety band 20.0 cm
If system will operate on multiple bands, the separation distance required shall be equal to, or greater than, the
band with the largest separation distance.
IC RF Exposure — Equipment operating in the public safety band should be installed and operated with the
following minimum distance of between the radiator and your body:
VHF public safety band (DDR-V) 261.5 cm - This distance must be maintained when a 10.5dBi antenna is used.
Low Band UHF public safety band 51.8 cm - This distance must be maintained when a 3.5dBi antenna is used.
UHF public safety band (DDR-U) 224.0 cm
700MHz public safety band (DDR-F) 187.0 cm - This distance must be maintained when a 5.5dBi antenna is used.
800MHz public safety band (DDR-S) 181.0 cm
If system will operate on multiple bands, the separation distance required shall be equal to, or greater than, the
band with the largest separation distance.
The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when
multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output
signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of
input power or gain reduction and not by an attenuator at the output of the device.
IC RF exposition — L'équipement fonctionnant dans la bande de sécurité publique doit être installé et utilisé
avec la distance minimale suivante entre le radiateur et votre corps
VHF bande de sécurité publique (DDR-V) 261.5 cm - Sa distance doit être maintenue lorsqu'une antenne de 10,5 dBi est utilisée.
Low Band UHF bande de sécurité publique 51.8 cm - Sa distance doit être maintenue lorsqu'une antenne de 3,5 dBi est utilisée.
UHF bande de sécurité publique (DDR-U) 224.0 cm
700MHz bande de sécurité publique (DDR-F) 187.0 cm - Sa distance doit être maintenue lorsqu'une antenne de 10,5 dBi est utilisée.
800MHz bande de sécurité publique (DDR-S) 181.0 cm
:
Si le système fonctionne sur plusieurs bandes, la distance de séparation requise est égale ou supérieure à la bande
avec la plus grande distance de séparation.
Nominale de puissance de sortie du fabricant de cet équipement est pour un fonctionnement à une seule porteuse.
Pour des situations où les signaux porteurs multiples sont présents, la cote devrait être réduite de 3,5 dB, en
particulier lorsque le signal de sortie est re-rayonnée et peut provoquer des interférences avec les utilisateurs de
bandes adjacentes. Cette réduction de puissance est effectuée au moyen d'une puissance d'entrée ou la réduction
de gain, et non par un atténuateur à la sortie du dispositif.