5014 Specifications
Sensor Type Thruline two-element 
line section
Elements APM or 43 series 
elements. Select two 
elements from the same 
series, with RFL power 
1/10 of FWD power.
Frequency Range
a
2 – 3600 MHz
Average Power Measurement, APM Elements, Forward 
or Reflected Direction
Power Measurement 
Rangea
0.1 W to 1 kW
Uncertainty
b
± 5% of reading (95% c.l.)
Peak/Average Ratio, Max 10 dB
Average Power Measurement, 43 Elements, Forward or 
Reflected Direction
Power Measurement Range 0.1 W to 10 kW
Power Measurement 
Uncertainty
± 5% of full scale 
average power 
(95% c.l.)
Peak Power Measurement, 43 Elements only, Forward 
direction only
Pulse Width, Min
2 – 25 MHz
25 – 100 MHz
> 100 MHz
15 µs
1.5 µs
800 ns
Rep. Rate, Min 15 pps
Duty Cycle, Min 1 x 10