15
5015 Specifications 
Power Measurement Characteristics
General Terminated average power
Frequency Range 40 MHz to 4 GHz
Power 
Measurement 
Range
–20.0 to +10.0 dBm (10 µW to 10 mW)
Maximum Power 2 W avg., 125 W peak for 5 µs
Peak/Average Ratio 12 dB maximum
Accuracy ± (5%  of  reading
a
 + 1.0 µW) 
(excluding mismatch uncertainty) 
No correction factors necessary
a. Above 40 °C, when measuring frequencies between 40 
and 100 MHz, add 1%.
Input Impedance 50 Ohms (nominal)
Input VSWR: 
Typical 
Maximum
1.03 (36.6 dB return loss) 
1.20 (20.8 dB return loss)
Input Connector Precision N Male
Output Connector SeaLatch
®
 USB type to host 
instrument
Power Supply From host instrument via cable 
connection