6
Setup
y Before first using the load, get a resistance baseline for future
maintenance. Refer to
“DC Resistance” on page 14 for instructions.
y Remove the shipping plugs from the load and replace them with
the vent plugs. Refer to
Figure 2 and Figure 3 to identify the plugs.
Thermoswitch Bird 8930 Loads can be equipped with an optional interlock
thermoswitch, P/N 8890-017. It is normally closed, opening at 226 °C
(439 °F), with a rating of 10A @ 120Vac and 5A @ 230Vac.
A control thermoswitch, P/N 8892-333, is used to control the blower
assembly. It is normally open, closing at 60 °C (140 °F), with a rating
of 10A @ 120Vac and 5A @ 230Vac.
To install or replace a thermoswitch, follow these instructions:
1. Replace both vent plugs with the shipping plugs.
2a. Interlock Thermoswitch: Supporting the load to prevent damage
to the RF connector, stand the unit on its front with the connector
down. In this position there is no danger of coolant spillage.
2b. Control Thermoswitch: Stand the unit on its back end, with the
connector up. In this position there is no danger of coolant spillage.
3. Remove the socket plug (or old thermoswitch), using a
9
16
"
hex wrench.
4. Insert the new thermoswitch. Sparingly apply pipe sealing
compound to the external threads, only, of the thermoswitch. Do
not contaminate the coolant with pipe sealant.
5. Check for coolant leaks upon completion.
WARNING
BOTH vent plugs must be used at all times when the unit is
operating or cooling. Failure to do so could result in an
explosion or severe burns.
WARNING
BOTH vent plugs must be used at all times when the unit is
operating or cooling. Failure to do so could result in an
explosion or severe burns.