Bird 8930 Series Semiconductor Termaline Coaxial Load Resistor
8
AC Power
Connection
The ac power supply required for this unit is 115/230 V, depending on
the model, @ 50/60 Hz, 1
φ. The blower is equipped with an IEC 320
“cold” (65
°C) ac inlet.
Connecting RF
Power
After installing the load, the RF transmission line can be attached
using standard coaxial line coupling kits.
“QC” Connector Coupling: Use 50 ohm coaxial cable such as
RG-218/U or -220/U (-17A or -19A), appropriate for the frequency and
power level of operation. Use a cable connector which will mate with
the one on the load.
CAUTION
Check the local electrical code for proper ac hookup prior to
operation of the unit. Make sure the neutral or return hookup is
only used for that purpose.
WARNING
Turn off ac power and RF power when attaching the power cable.
WARNING
Never attempt to connect or disconnect RF equipment from the
transmission line while RF power is being applied.
Leaking RF energy is a potential health hazard.