Manual

Maintenance
21
Specifications
Frequency Range
dc – 28 MHz
Power Rating
10 kW continuous duty
Impedance, Nominal
50 ohms
VSWR
1.10 max
VSWR Stability
< 0.1 dB, from 0 to 100% rated power
at stability frequency
Stability Frequency
13.56 MHz ± 10 kHz
Connector
“QC” Type, Female LC normally supplied
AC Power
–115
–230
115 V +10, –6% @ 50/60 Hz ±3%
230 V +10, –6% @ 50/60 Hz ±3%
AC Line Power Rating
460 W max
Fuse Rating
IEC (5 x 20 mm) Type T
115 Vac
230 Vac
3.15 A
1.25 A
Thermoswitch
Interlock (Optional)
Fan Control
Normally closed. Opens at 226 °C (439 °F)
Normally open. Closes at 60 °C (140 °F)
Thermoswitch Rating
115 Vac
230 Vac
10 A
5 A
Temperature, Operating
+5 to +40 °C (+41 to +104 °F)
Temperature, Storage
40 to +45 °C (– 40 to +113 °F)
Altitude
*
* Derate RF power by 250 W for every 305 m (1,000 ft.) above 1,520 m
(5,000 ft.), up to a maximum of 3,050 m (10,000 ft.).
1520 m (5000 ft.)
Humidity
95% noncondensing max
Cooling method
Oil dielectric and forced air convection
Dimensions
29
7
8
”L x 9.5”W x 33
3
8
”H (759 x 241 x 847 mm)
Weight, Nominal
142 lb. (64.4 kg)
Finish
Black Epoxy Resin