Product specifications
SLCS Programming Manual
Rev. 1.24
- 13 -
p9 : Bold
N : Normal B : Bold
p10 : Text Alignment(Optional)
F : p1 means the position of the first character in text string - Left alignment
L : p1 means the position of the last character in text string - Right alignment
R: Write text sting form right to left.
(BIXOLON → NOLOXIB)
♣ This parameter is for alignment of text lines.
‘DATA’ : The various data types can be used in the data field as followings.
1) Fixed text string : ‘ Text String’
2) Variables declared in template by SV command : Vnn
3) Counters declared by the SC command : Cn
♣ 1) , 2) and 3) can be mixed together
Example
T50,100,3,1,1,0,0,N,N,’ BIXOLON Label Printer’
T50,100,3,1,1,0,0,N,N,’Manufacturer :’V00
T50,100,3,1,1,0,0,N,N,V00
T50,100,3,1,1,0,0,N,N,’Manufacturer :’C0
T50,100,3,1,1,0,0,N,N,C0
♣ If you want to print
’ or \ then you must type like \’ or \\ .