User manual

55
6 Specifications
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes
over an ambient temperature range of 23 °C ± 5 °C. Specifications are subject to change
without notice.
Environmental Conditions:
This power supply is designed for indoor use and operated with maximum relative humidity of
95%.
Model
9115
Output Rating
Voltage
0 80 V
Current
0 60 A
Max Output Power
1200 W
Load Regulation
1
(± % of output + offset)
Voltage
< 0.01 % + 5 mV
Current
≤ 0.1 % + 10 mA
Line Regulation
(± % of output + offset)
Voltage
< 0.02 % + 1 mV
Current
< 0.02 % + 1 mA
Programming/Readback
Resolution
Voltage
1 mV
Current
1 mA
Programming/Readback Accuracy
Voltage
0.02 % + 30 mV
Current
≤ 0.1 % + 0.1% FS
Ripple (20 Hz 20 MHz)
Voltage
60 mVpp
Current
100 mArms
Temperature Coefficient
(0 °C 40 °C)
(± % of output + offset)
Voltage
0.02 % + 30 mV
Current
≤ 0.05 % + 10 mA
Readback Temperature Coefficient
(0 °C 40 °C)
(± % of output + offset)
Voltage
0.02 % + 30 mV
Current
≤ 0.05 % + 5 mA
Efficiency
> 88% (full load)
Power Factor
> 0.99 (full load)
Standard Interface
USBTMC, GPIB, RS-232, RS-485
Power Requirements
115/230 VAC ± 10 %, 47 Hz 63 Hz
Dimensions (WxHxD)
415mm x 44 mm x 500 mm
Weight
8.5 kg
Operating Temperature
0 °C40 °C
Storage Temperature
-20 °C - 70 °C
1
With remote sense connected