User manual

19
OVP:turns on/off the
overvoltage protection
SET: set up the overvo
ltage protecting
point.
OCP:turns on/off the
overcurrent protection
SET:
set up the overcurrent protecting
point.
OPP:turns on/off the overpower
protection
SET: set up the overpower protecting
point.
FF
FF
=
=
CV TO CC:
Enable/disable the protection of the change
from CV to CC mode
CC TO CV:
Enable/disable the protection of the change
from CC to CV mode
4. SERIES/PARALLEL SETTING
Press
in the second screen of Menu Setting to enter
SERIES/PARALLEL menu.
L
TL
T
FF
=
=
T
SELECT MODE: Choose
series or parallel operation
mode.
MASTER/SLAVE:
Refer to “Series/Parallel Setting
section
for the detailed setting
procedure of MASTER/SLAVE mode.
5. INFORMATION
Press
in the second screen of “Menu Settingto enter
INFORMATION screen.