User manual
 35
countdown of the timer. Once it reaches down to zero, the supply will turn off 
the output automatically. 
=
.
ce55
:
:
.
4.8  Series (cascade) / Parallel Mode Setting 
The  XLN3640/XLN6024/XLN8018/XLN10014  uses the series/parallel mode 
(4 supplies maximum) to increase the output power capability. By connecting 4 
instruments in parallel, the combined unit can offer 36 V/160 A power output. 
By connecting 4 XLN10014 units in series, the combined supply can  output 
400 V/14.4 A. Note that you cannot perform both parallel and series mode at 
the same time. Series connection will be off once series (cascade) / parallel 
connection function is turned on. 
4.8.1  Parallel Connection Setting 
While connecting four sets of XLN3640/XLN6024/XLN8018/XLN10014  in 
parallel, the wiring should be setup like the following: 
After wiring is complete, configure one  XLN3640 /  XLN6024 /  XLN8018 / 
XLN10014 as the Master and the other three are Slave A, B and C. After one of 
the supplies is configured to be the Master, it will start searching for all Slaves 