Installation manual
D15  Oven  temperature
Here  it  is  possible  to  read  the  current  oven  temperature,  P1.  In  the  field  next  to  ”Temperature”,  the  current 
temperature  is  shown.  If  ERR  appears,  the  sensor  circuit  is  defective.  In  the  field  next  to  ”Time”,  an 
adjustment  value  between  80  and  120  (default  100)  is  shown.  To  
adjust  the  temperature,  press  the  time  key 
until  the  digit  in  the  display  flashes.  Then  adjust  upwards  or  downwards  until  the  correct  temperature  is 
shown.  Finally,  press  the  time  key  again  to  save  the  setting.  The  temperature  can  be  adjusted  by  +-  50°F  (+- 
10°C).
TEST  MODE  D16-D20
D16  Core  temperature  (This
  function  is  not  available  on  B  models).
C  and  K  models  can  use  only  one  core  temperature  probe,  it  is  possible,  however,  to  test  core 
temperature  probes  1  and  2.
Here  it  is  possible  to  read  the  current  temperature  of  the  core  temperature  sensor,  P2  +  P2A.  In  the  field  next 
to  ”Temperature”,  the  current  temperature  is  shown.  If  ERR  appears,  the  sensor  circuit  is  defective.  In  the 
field  next  to  ”Time”,  an  adjustment  value  between  80  and  120  (default  100)  is  shown.  To  adjust  the 
temperature,  press  the  time  key  until  the  digit  in  the  display  flashes.  Then  adjust  upwards  or
  downwards 
until  the  correct  temperature  is  shown.  Finally,  press  the  time  key  again  to  save  the  setting.
The  temperature  can  be  adjusted  by  +-  50°F  (+-  10°C).  You  change  between  the  various  measuring  points 
of  the  core  temperature  probe  by  pressing  the  step  key.
1=  Core  temp.probe  1,  point  1,     
2=  Core  temp.probe,  point  2,      3=  Core  temp.probe  1,  point  3.
4=  Core  temp.probe  2,  point  1,      5=  Core  temp.probe,  point  2,      6=  Core  temp.probe  2,  point  3.
D17  Steam  generator  temperature  (Available  on  K  models  only).
Here  it  is  possible  to  read  the  current  steam  generator  temperature,  P3. 
In  the  field  next  to  ”Temperature”, 
the  current  temperature  is  shown.  If  ERR  appears,  the  sensor  circuit  is  defective.  In  the  field  next  to  ”Time”, 
an  adjustment  value  between  80  and  120  (default  100)  is  shown.  To  adjust  the  temperature,  press  the  time 
key  until  the  digit  in  the  display  flashes.
  Then  adjust  upwards  or  downwards  until  the  correct  temperature  is 
shown.  Finally,  press  the  time  key  again  to  save  the  setting.  The  temperature  can  be  adjusted  by  +-50°F  (+- 
10°C).
D18  Drain  temperature
Here  it  is  possible  to  read  the  current  steam  generator  temperature,  P4.  In  the  field  next  to  ”Temperature”, 
the  current  temperature  is  shown.  If  ERR  appears,  the  sensor  circuit  is  defective.  In  the  field  next  to  ”Time”, 
an  adjustment  value  between  80  and  120  (default  100)  is  shown.  To  adjust  the  temperature,  press  the  time 
key  until  the  digit  in  the  display  flashes.  Then  adjust  upwards  or  downwards  until
  the  correct  temperature  is 
shown.  Finally,  press  the  time  key  again  to  save  the  setting.  The  temperature  can  be  adjusted  by  +-  50°F  (+- 
10°C)  (approx.  33°F  [0.5°C]  per  step).
D20  Door  sensor
Here  it  is  possible  to  read  the  status  of  and  calibrate  door  sensor  1  =  SE1  and  2 
=  SE1A.  You  change 
between  door  sensor  1  and  2  by  pressing  the  step  key.  After  some  time,  the  text  “DOOR  SENSOR”  changes 
to  show  the  status  of  the  sensor:  >CLOSED<,  >OPEN<,  >SENS  ERROR<.  You  start  the  calibration  by 
pressing  the  exhaust  key.
How  to  calibrate:
1.  Press  damper  key        
2.    >CLOSE<  flashes         3.  Close  the  door
4.  Press  damper  key         5.    >OPEN<  flashes         6.  Open  door  in  the  first  step
7.  Press  damper  key         8.    >CALIB  OK<  or  >CALIB  ERR<  appears   
    9.  Press  damper  key  to  confirm
In  the  display  next  to  the  temperature  key,  it  is  possible  to  read  the  current  value  (0  –  120).  In  the  display 
next  to  the  time  key,  it  is  possible  to  read  the  set  point.
TEST  FUNCTIONS  D21-28
D21  Water  level  (Available  on  K  models  only).
Here
  it  is  possible  to  read  the  status  of  Se2.  In  the  display  next  to  ”Time”,  the  conductivity  is  shown  and  it  is 
indicated  whether  the  water  level  is  high  or  low.  XX|LO=  low  water  level,  XX|HI=  high  water  level.  XX  = 
conductivity  of  the  water.  Default  setting  is  approx.  80 
with  no  water  and  40.60  with  water.  The  better  the 
13