Error Codes
2 DOOR OPEN Oven door open
3 GENRA HOT Generator too hot
4 OVEN HOT Oven too hot
5 FAN HOT Fan too hot
6 DRAIN > 75 Drain too hot 167°F (above 75°C for 5 minutes)
7 OVEN SENS Oven sensor defective
8 PROBE SENS Core temperature probe defective
9 GENER SENS Steam
generator sensor defective
10 DRAIN SENS Drain sensor defective
11 WATER SHOR Water shortage (steam generator was not filled within 2 minutes)
12 SSR HOT Solid State relay cooling plate too hot
13 GENER > 130 Temperature sensor in generator reports temp. exceeds 266°F (130°C)
14 FAN SPEED Fan too slow
15 CPU HOT Temperature of
CPU board too high >140°F (> 60 °C)
16 IO BRD HOT Temperature of IO board too high >140°F (> 60 °C)
17 Not in use
18 DATA ERROR Memory error
19 WRONG LANG Wrong language
20 NO COM IO No data communication between CPU and IO board
21 PROGRAM ER Program error
22
NO RESTART Restart not possible, too long without power
23 OVEN WARM Oven too hot when CombiWash starts 248°F (120°C)
24 DRAIN ERR Drain blocked, after 10 sec. of draining, water level in generator still high.
25 PROBE ERR 1 or 2 of the 3 elements in core temperature probe defective
26
Not in use
27 Not in use
28 ALARM ERR Configuration error in main alarms (3, 4, 5, 12)
29 Not in use
30 Not in use
31 Not in use
32 Not in use
33 Not in use
34 WATER PRES Water pressure too low
35 Not in use
36 NO SOAP Detergent insufficient
37
Not in use
38 Detergent in oven chamber
39 Not in use