Installation manual

5
Drain connection
From the factory, the BKI ovens are equipped with a drain system that removes surplus water from the oven
chamber. This water may be condensed water from the products, or it may occur when the oven chamber is
cooled down with cold water, or when the oven chamber is
cleaned.
!
!
CAUTION: Connection must be carried
out by an authorised plumber, to an open
or to a closed drain.
!
!
CAUTION: The drain must never end
directly beneath the oven.
The drain must be of stainless steel or an equally temperature-
resistant material, have a diameter of at least 2” (50 mm) and a fall
of at least or 5%.
Electrical connection/survey of supply lines
! The electrical connection must be carried out by an authorised electrician in accordance with existing
rules and regulations.
! The wiring diagram is located in the motor compartment.
! The terminal for the electrical connection is located behind the right side plate.
CAUTION: An approved plug outlet or a safety cutout must be located close to the
oven so that the oven can be disconnected during installation and repair. The safety
cutout must be able to cut off all poles
with a total distance of break of at least .12” (3
mm). Each of the two units in a stacked arrangement (CombiPlus) must have its own
plug outlet or safety cutout
!
!
The warranty does not cover incorrect connection.
!
!
Supply lines - survey (applies to all models (C, B, K, CPE, BPE, KPE)
(All cross sections in mm² )
1.06
1.08 - 1.10 -
1.12
1.08 - 1.10 -
1.12
1.16
1.16
1.20
1.20
2.10
2.14
2.10
2.14
Fuse
18 kW
Fuse
24 kW
Fuse
36 kW
Fuse
27 kW
Fuse
16A
5x4
35A
5x10
50A
5x16
63A
5x10
50A
16A
4x4
35A
4x10
50A
4x16
63A
4x10
50A
415V 3N ~ 50/60 Hz
400V 3N ~ 50/60 Hz
400V 3 ~ 50/60 Hz
440V 3 ~ 50/60
Hz
200V 3 ~ 50/60 Hz
230V 3 ~ 50/60 Hz
230V 1 ~ 50/60 Hz
480V 3 ~ 50/60 Hz
208V 3 ~ 50/60 Hz
16A
5x4
25A
5x10
50A
5x10
50A
5x10
50A
16A
4x4
25A
4x10
50A
4x10
50A
4x6
35A
35A
4x16
63A
4x25
100A
4x35
125A
4x25
80A
25A
4x10
50A
4x25
80A
4x35
100A
4x25
80A
50A
3x25
80A
*
*
*
*
*
*
16A
4x4
25A
4x6
35A
4x10
50A
4x6
35A
25A
4x10 50A
4x25
80A
4x35
100A
4x25
80A
1.06
9 kW
5x2,5
4x2,5
5x2,5
4x4
4x4
3x10
4x2,5
4x4
4x2, 5
*Not Possible Recommended Supply Line: H07RN-F