Exhaust
The BKI ovens are equipped with an open/direct exhaust system that
removes surplus humidity from the oven chamber. The exhaust system has
an electrically operated damper. The exhaust tube can be connected to a
ventilating system. In that case, a special extraction funnel is fitted to avoid
suction directly from
the oven chamber. This extraction funnel can be
ordered from BKI. The scope of supply also includes a specially designed
extraction hood, see adjacent illustration.
If an extraction hood is installed in the ceiling above the oven, it should project
20” (50 cm) over the front of the oven. The suction
effect should be 400 800
33
m/h (523 - 1046 yd /h).
The ventilation motor can be controlled directly from the oven. This means that
the ventilation starts when a program is started and runs for 10 minutes after the
program is completed.
Checking Before Use
The oven should be checked before you start using it.
On The Outside
! Check that the oven has not been damaged in
transit (dents, scratches, etc.)
! Check/adjust oven door
Connections
! Check for correct water connection
! Turn on water supply
! Check for leaks
! Turn off water supply
! Check and clean dirt filter
! Turn on water supply again
! Check handshower
! Check for correct electrical connection
Oven chamber
! Check that filter housing is mounted correctly
! Check interior light
Operation panel
! Check and adjust, if necessary, each of the
preset values
! Check connection to trip tray
! Check for correct mounting of drip tray
! Check for correct fall of hose from drip tray,
and check for leaks
! Check for correct exhaust and drain
connection
! Clean oven
! Check/adjust the height and check that the
oven is placed level (horizontally)
! Clean oven
! Heat up the oven at 482°F (250°C) for
approx. 5 min.