5.3. PROGRAMMING
The HART interface of the EasyTREK provides for access to the whole parameter set and possibility of their programming. Parameter set can be reached in two
different ways: by the use of the
- EView software run on the PC connected through HART modem to the loop or
- Nivelco made MultiCONT multi-channel process control unit.
Since these access methods differ in their form and handling present manual does not review them. The information is contained in the relevant descriptions and
user’s manuals.
5.3.1. MEASUREMENT CONFIGURATION
P00: - c b a Engineering Units FACTORY DEFAULT: 000
Programming of this parameter will result in loading the factory default with the corresponding engineering units.
Therefore all parameters should be set again!
a Operation
0 Liquid level measurement
Engineering units
(according to “c”)
b
Metric US
0 mft
1 cm inch
c Calculation system
0 metric
1 US