Technical data

BKI 03 ATEX 027X spa3804a0600p_06
7 / 44
2.3 SPECIAL DATA
SPECIAL DATA FOR PP, PVDF AND PTFE TRANSDUCERS (ALSO APPLIES TO Ex MODELS)
Type
SP-39 - SP-38- SP-37- SP-36- SP-34-
Transducer material PP, PVDF PTFE PP, PVDF PTFE PP, PVDF PTFE PP or PVDF PP or PVDF
Max measuring distance * (X
M
) [m / ft] 4/13 3/10 6/20 5/16 8/26 6/20 10/33 15/49
Min. measuring distance*
(Dead band) [m / ft]
0.2/0.65 0.25//0.82 0.25//0.82 0.25//0.82 0.35/1.2 0.35/1.2 0.35/1.2 0.45/1.5
Total beam angle (-3dB)
Measurement frequency 80 kHz 80 kHz 50 kHz 60 kHz 40 kHz
Process connection 1” BSP and 1 ½” BSP/NPT 1” BSP and 2” BSP/NPT 1” BSP and 2” BSP/NPT 1” BSP 1” BSP
* (from the transducer face)
2.4 ACCESS ORIES
Certificate of Warranty
Installation and Programming Manual
Declaration of Conformity
2.5 ORDER CODES (NOT ALL COMBINATIONS ARE AVAILABLE)
EasyTREK
S
P–3
HOUSING MATERIAL CODE RANGE M/FEET CODE PROCESS CONNECTION CODE OUTPUT / EX CODE
PP A 15/49 4 1”; 2” BSP thread 0 4 … 20 mA / HART / LOGGER 3
PVDF B 10/33 6 2” NPT thread N 4 … 20 mA / HART 4
PTFE / PP T 6/20 ; 8/26 * 7 1” BSP quick conn. / PP F 4 … 20 mA / HART / LOGGER / Ex 7
5/16 ; 6/20 * 8 Bracket 200 mm K 4 … 20 mA / HART / Ex 8
3/10 ; 4/13 * 9 Bracket 500 mm L 4…20mA / Relay / HART
H
Bracket 700 mm M 4…20mA / Relay / HART / LOGGER A
The order code of an Ex version should end in ‘Ex
* Measuring range depends on the material of the transducer