Service manual
Multi-Deck Warmer Installation
8
16 in
[407 mm]
10 1/2 in
[266 mm]
56 3/16 in
[1426 mm]
Floor
Model
41 1/8 in
[1045 mm]
Counter
Model
10 5/16 in
[263 mm]
8 1/16 in
[205 mm]
25 15/16 in
[659 mm]
23 1/8 in
[587 mm]
25 15/16 in
[659 mm]
WIDE VERTICAL
VERTICALCASCADE
WIDTH + 4 13/16 in [122 mm]
WIDTH + 2 9/16 in [65 mm]
WIDTH + 1/2 in [13 mm]
20 5/8 in
[525 mm]
10 5/8 in
[269 mm]
20 5/8 in
[523 mm]
10 5/8 in
[269 mm]
Counter Model
Counter mounted units must be mounted on a level surface that can support the weight of the unit and its
contents. Use a carpenter’s level to level the unit.
These units are to be sealed to the counter if required by local health codes. Seal the perimeter of the units
to the counter using a silicone-type sealant (Dow Corning RTV #732 or equivalent).
Caster Model
Caster mounted units must be moved to a permanent location and the two swivel casters locked before
using.
Wiring
A wiring diagram for your specific model is included in this manual. The wiring diagram provides electrical
specifications, an electrical schematic and a parts list. Refer to this wiring diagram and the unit rating plate
for electrical information.
All electrical connections should be in compliance with the NEC and all applicable local codes by a licensed
electrician. Refer to the wiring diagram furnished with your unit for the electrical specifications.
Dimensions & Weights
Electrical Specifications – refer Wiring Diagram listed for each model.
Model Diagram Width Wiring Diagram
Shipping Wt.
Counter Floor
MDW36-3C CASCADE 36 in [914 mm] EB68694600 300 lb [136 kg] 360 lb [163 kg]
MDW36-3V VERTICAL 36 in [914 mm] EB68694700 200 lb [91 kg] 240 lb [163 kg]
MDW36-3WV WIDE VERTICAL 36 in [914 mm] EB68694800 330 lb [150 kg] 390 lb [177 kg]
MDW48-3C CASCADE 48 in [1219 mm] EB68693600 380 lb [172 kg] 440 lb [200 kg]
MDW48-3V VERTICAL 48 in [1219 mm] EB68693700 280 lb [127 kg] 320 lb [145 kg]
MDW48-3WV WIDE VERTICAL 48 in [1219 mm] EB68693800 420 lb [190 kg]
480 lb [218 kg]
Figure 3
3 Shelf Merchandisers