Specifications

DVI Switch
15
ASCII ‘v’ (Hex 76 or Decimal 118)
Causes the system to display the firmware version
number.
The device will respond with:
Firmware Version: X.Y where ‘X.Y’ is the numeric
version level of the firmware software.
ASCII ‘A’ or ‘a’ (Hex 41/61 or Decimal 65/97 )
Enters Auto mode. The user must select the desired
detection method by entering a number from 1 to 3
within 20 seconds. Values outside this range or delaying
entry longer than 20 seconds will result in an error
message: Invalid entry! Current detection stays
the same.
The device will respond with:
Auto mode selected
Detection Method
-----------------------------
1 = Vertical sync
2 = 5V Power
3 = Vertical sync & 5V power
-----------------------------
Current detection is [X](1-3)?
Where ‘X’ is the current detection method of 1, 2 or 3.
In Auto mode, the device automatically switches to the
video & audio input source that is active.
“Active” means that video signal has sync signal, it does not
mean there is a non-static screen!