Specifications
12
3. Press the hopper’s Pushbutton, located in the top right corner of the front side, once. The hopper’s red
Indicator LED should begin blinking at a rate of once per second.
Once this is done, the configuration procedure can be completed. NOTE: The hopper will remain in the
“Power ON” state for only 1 minute, so perform the configuration immediately after entering this mode. If
the validator power turns off in the middle of configuration, it will be unsuccessful and must be
reconfigured from the beginning. To take the hopper out of the “Power ON” state before the minute is up,
press the Pushbutton once again.
Configuration Card Settings
Both the Trilogy and APEX/XLC cards are laid out the same, so make the following selections when filling
out either:
Section 1
– “Pulse” (Trilogy) or “Pulse/Serial” (APEX/XLC)
Section 2 – “1”
Section 3 – “Fast” and “Flashing”
Section 4 – Fill in the ovals for only the bills you want to be enabled; the rest will be disabled
(Bill/Note 1 = $1.00; Bill/Note 2 = $5.00; Bill/Note 3 = $10.00; and Bill/Note 4 = $20.00).
Section 5 – “Low” and “All 4 Ways”
Coin Acceptor Configuration
This section provides the procedure for performing the only three configuration changes that may be
required for the Coin Acceptor. A Technical Manual with additional details may be downloaded and
printed from the Money Controls website. The pertinent manuals are the “Condor Plus Technical Manual”
(TSP018) and the “Condor Plus/Premier MechTool Manual” (TSP020), which can both be found at
www.moneycontrols.com/support/technical_manuals.asp.
Before Performing Any Configuration Procedures
In order to keep the Coin Acceptor’s power on during the entire configuration procedure, please perform
t
he following:
1. Lift up the Coin Door on the front door of the AC401-COIN to turn the acceptor’s power on, and then
allow it to reclose.
2. Verify that the Coin Acceptor power is on, as indicated by a lit green LED on its side.
3. Press the hopper’s Pushbutton, located in the top right corner of the front side, once. The hopper’s red
Indicator LED should begin blinking at a rate of once per second.
Once this is done, configuration of the acceptor may proceed. NOTE: The hopper will remain in the
“Power ON” state for only 1 minute, so perform the configuration immediately after entering this mode. If
the Coin Acceptor power turns off in the middle of configuration, it will be unsuccessful and must be
reconfigured from the beginning. To take the hopper out of the “Power ON” state before the minute is up,
press the Pushbutton once again.
To Erase All Currently Programmed Coins/Tokens
1. Turn the Rotary Switch to position 0, and make sure the LED is solid green before proceeding.
2. Press and hold the Program Button until the LED begins to flash yellow, and then release it.
3. With the LED still flashing yellow, turn the Rotary Switch to position 9.
4. Press the Program Button two times, the second time within 0.5 seconds
of the first. The LED
should turn red for 1 second, and then return to flashing yellow.
5. Return the Rotary Switch to position 0.
6. Press and hold the Program Button until the LED returns to solid green, and then release it.
For more information visit www.Gumball.com | 800-260-0010 | +1-214-550-5079