Specifications

15
3. Remove the Battery Hopper from the cabinet by sliding it forward slowly, while applying gentle
upward pressure, until it releases.
4. Take the battery down from the bracket in the top left corner, and relocate it in the open area to the
right of the hopper. Install it on the bottom of the cabinet, and push it all the way to the back.
5. Locate the AC Power Harness. Insert the Panel-Mount connector (refer to Figures 7 & 8) into the hole
in the rear of the cabinet from the inside. Make sure that the connector’s Notch is facing upward as it
is inserted through the hole. Gently push it until it ‘snaps’ into place, with its two barbs “grabbing” the
outside rear of the panel. Wiggle it a little bit to ensure that it is locked in place.
6. Reroute the Main Harness’ white, 2-position battery connector (disconnected in step 2) underneath the
green metal plate upon which the hopper sits, toward the battery on the right.
7. Connect this battery connector to the Female connector of the AC Power Harness (refer to Figure 7).
8. Next, reinstall the hopper. The hopper has mounting grooves on its underside that match up with the
keyed pattern cut along the sides of the green hopper plate. Position the hopper on top of the plate,
and maneuver it until it drops down. Slide it backwards until it stops and the hopper plate’s connector
inserts into the hopper’s 12-pin connector.
9. Finally, connect the Male connector of the AC Power Harness (refer to Figure 7) to the white two-
position connector located on top of the battery. This will power-up the system.
NOTES
After performing this procedure, either of the supplied battery chargers can be plugged directly into
the rear of the changer (refer to Figure 9) to maintain the battery while the machine is operating
normally.
DO NOT connect a discharged battery this way in order to recharge it while inside the cabinet. Always
fully recharge a discharged battery BEFORE installing it inside the AC401.
Figure 9
Applying AC Power
Figure 8
Panel
-
Mount Conn.
Notch
Figure 7 – AC400.16-H
AC Power Harness
Panel-Mount Conn.
Female Conn.
Male Conn.
For more information visit www.Gumball.com | 800-260-0010 | +1-214-550-5079