User's Manual

85
CHAPTER 5: Measurements
The scrollbar indicates that there are more test results. Use the down-arrow on
OMNIScanner’s keypad to scroll through the list and view results for the other six
pair combinations.
Press or to toggle between the ELFEXT results for
OMNIScanner2 and OMNIRemote.
Press (Graph) to display the ELFEXT graph for the currently
highlighted pair combination. ELFEXT is displayed for the frequency indicated by
the cursor position.
Press (Pairs) to view ELFEXT graphs for other pair combinations.
Press ESC to exit the ELFEXT screen.
5.3.7 ACR/B
ANDWIDTH
Attenuation to Crosstalk Ratio (ACR) is an indication of how much larger the
received signal is compared to the Near End Crosstalk (NEXT) on the same pair.
ACR is calculated from the measured NEXT and Attenuation. The ACR value is
computed at each measured Attenuation frequency. The worst-case ACR is
reported for each pair combination.