5.0 Hayes Emulation Mode
Table 5-1(continued). Hayes Compatible Commands.
COMMAND FUNCTION/EXPLANATION
\N V.42 Mode *
1
\N0 Disables error correction.
\N1 Enables mandatory mode for error correction.
\N2 Disables error correction.
\N3 Enables automatic mode for error correction.
\P V.42 Protocol *
1
\P0 Selects LAPM protocol only.
\P1 Selects MNP protocol only.
\P2 Selects LAPM/MNP protocol (MNP as alternate).
\Q V.42 Flow Control *
1
Two parameters may be used
(e.g., \Q0,1; \Q3,2 , etc.). First parameter specifies DCE-
DTE flow; second (optional) specifies DTE-DCE flow control.
0 None (no flow control).
1 CTS on/off or RTS on/off (CTS for DCE-DTE flow
control, RTS for DTE-DCE).
2 DC1/DC2 flow control.
3 DC1/DC3 flow control (default for DCE-DTE and
DTE-DCE).
\S View Status Of V.42-Related Configuration
No parameters.
\T Load Inactivity Timer
\T0 Disables inactivity timer.
\Tn Sets inactivity timer to n minutes (where n = 0 to 60).
\V V.42 Result Codes
1
\V0 Activates regular V.42 result codes.
\V1 Activates extended V.42 result codes.
\X V.42 Pass-Through Flow Control *
1
\X0 Enables pass-through flow control.
\X1 Disables pass-through flow control.
NOTE: DTE speed and parity are set automatically. Auto-answer is enabled or disabled by S register S0.
1
Option can be changed only when Modem is off-line.Default settings (where applicable) are in bold face.
* If user profile 1 is active, options are controlled (for Hayes mode operation) by given commands or
Summary Setup. Do not change via front panel (except via Summary Setup).