User's Manual

6
DUAL PORT RS-232 SERIAL INTERFACE
NOTE
Be sure to set the address selections and jumper options before
installation.
Each serial port on the Dual Port RS-232 Serial Interface occupies 8
consecutive I/O locations. A DIP switch is used to set the base address for
these locations. Be careful when selecting the base address as some selections
conflict with existing PC ports. The following table shows several examples
that usually do not cause a conflict. SW1 sets the I/O address for Port 2 (the
upper connector), while SW2 sets the address for Port 1 (the lower
connector).
Address Binary Switch Position Setting
Hex A9 A0 1 2 3 4 5 6 7
280-287 1010000XXX OFF ON OFF ON ON ON ON
2A0-2A7 1010100XXX OFF ON OFF ON OFF ON ON
2E8-2EF 1011101XXX OFF ON OFF OFF OFF ON OFF
2F8-2FF 1011111XXX OFF ON OFF OFF OFF OFF OFF
3E8-3EF 1111101XXX OFF OFF OFF OFF OFF ON OFF
300-307 1100000XXX OFF OFF ON ON ON ON ON
328-32F 1100101XXX OFF OFF ON ON OFF ON OFF
3F8-3FF 1111111XXX OFF OFF OFF OFF OFF OFF OFF
Typically COM1:=3F8h; COM2:=2F8h; COM3:=3E8h; COM4:=2E8h
If you do not see an address in the table that is compatible with your software,
3. Address Selection