User's Manual

107
CHAPTER 9: Troubleshooting
4. Change the QINACTITV value to a longer value, or use *NONE to deactivate
the inactivity timeout.
9.5.4 TN5250
E
C
ONNECTION
S
TATUS
M
ESSAGE
The print server reports the success or failure of an attempt to communicate with
the host by printing a brief connection status message on each attached printer.
The connection status message will look somewhat like:
AS/400 Host Communication Status:
Connection attempt succeeded
Host system S101256R
Printer name TNPRT00
Status code I902 - Session successfully started
The message will show whether the connection succeeded or not, the name of the
host AS/400 which this print server is connected to, the printer name, and the
session status. (If there is no host or printer name in the message, it’s because the
host AS/400 did not send that information with the status message.)
The status code (I902) shown in the above example is the normal code indicating
successful host communication. The possible values of the status code and
suggested actions to take for that status code are as follows:
0101 = Host not responding to pings
This message usually indicates one of the following:
TCP/IP has not been started on the host.
The host’s IP address has not been correctly configured on the print server.
The print server has not been correctly connected to the LAN.
0102 = Host rejected connect to Telnet port
The host answers pings, but rejects a TCP/IP connect attempt, probably because its
Telnet server has not been started.