Specifications

Copyright © 2012 Black Box Network Services. All Rights Reserved.
724-746-5500 | blackbox.com 135
Setup
Send RS-232 String Action and RS-232 String
Check Send RS-232 String Action to send the specified RS-232 String. Clearing this setting will result in no RS-232 String
being sent.
The RS-232 String is expressed in hexadecimal format. For example: 9F 80 60 3F 00 BE
DTR (Data Terminal Read) / RTS (Ready To Send) Action
If enabled then sets the specified RS-232 Output line to the specified voltage level. If cleared, then the specified RS-232
Output line is unchanged.
Configuration
Bits per Second
Select the Baud rate in bit per second from the drop down list. The iCOMPEL currently supports rates between 110 and
460800.
Data Bits
The number of data bits to use. Select from either 7 or 8.
Stop Bits
The number of stop bits to use. Select from either 1 or 2.
Parity
The number of stop bits to use. Select from Odd or Even.
Use Local Override
If enabled, then this will use the specified Local Override settings rather then the default Channel settings.
Note: This section is only shown if the iCOMPEL is either a Channel Subscriber or a Channel Publisher.
9.3.5 Interactivity
The iCOMPEL can programmed to respond to inputs from:
USB Touch Screens
RS-232 modem control inputs
Remote Keypad Buttons
This page allows these inputs to be enabled and configured.
NOTE Some features may depend on installed feature keys.
Touch
Status
The Status field indicates the current state of the Touch system. It can indicate that:
No Touch Screen is connected
Touch Screen is connected, but is not Calibrated
Touch Screen is available