Server User Manual

where network_connection is the name of the network connection as displayed in Control
Panel -> Network Connections, login is the dial-in username, and password is the dial-in
password for the connection.
To initiate a pre-configured dial-up connection under Linux, use the following Start
Command:
pon network_connection
where network_connection is the name of the connection.
Enter the command or path to a script to stop the OoB connection in Stop Command.
To stop a pre-configured dial-up connection under Windows, use the following Stop
Command:
cmd /c start "Stopping Out of Band Connection" /wait /min rasdial network_connection
/disconnect
where network connection is the name of the network connection as displayed in Control
Panel -> Network Connections.
To stop a pre-configured dial-up connection under Linux, use the following Stop Command:
poff network_connection
To make the OoB connection using SDT Connector:
Select the console server and click Out Of Band. The status bar will change color to indicate that
this console server is now accessed using the OoB link rather than the primary link.
When you connect to a service on a host behind the console server, or to the console server itself, SDT
Connector will initiate the OoB connection using the provided Start Command. The OoB connection
does not stop (using the provided Stop Command) until you click off Out Of Band under Gateway
Actions; then the status bar will return to its normal color.
6.6 Importing (and exporting) preferences