Server User Manual

Note All console servers have the snmptrap daemon to send traps/notifications to remote SNMP
servers on defined trigger events as detailed above. LES1408A, LES1416A, LES1432A,
LES1448A, LES1308A, LES1316A, LES1332A, LES1348A,
LES1208A-R2, LES1216A-R2,
LES1232 and LES1248A-R2
console servers also embed the net-snmpd daemon. It accepts
SNMP requests from remote SNMP management servers and provides information on network
interface, running processes, etc. (refer to Chapter 15.5Modifying SNMP Configuration for
more details).
7.5.4 Nagios alerts
To notify the central Nagios server of Alerts, NSCA must be enabled under System: Nagios and Nagios
must be enabled for each applicable host or port under Serial & Network: Network Hosts or Serial &
Network: Serial Ports (refer to Chapter 10).
7.6 Logging
The console server can maintain log records of auto-response events and log records of all access and
communications events (with the console server and with the attached serial, network and power
devices).
A log of all system activity is also maintained by default, as is a history of the status of any attached
environmental monitors.
7.6.1 Log storage
Before activating any Event, Serial, Network or UPS logging, you must specify where those logs are to be
saved. These records are stored off-server or in the console server USB flash memory.
_____________________________________________________________________
724-746-5500 | blackbox.com Page 146