May 2006 MT1000A-13-R3 MT1000A-85-R3 T1 Fiber Multiplexer CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.
Quick Start Guide If you are familiar with the MT1000A, use this guide to prepare it for operation. Perform the following steps. 1. Installing MT1000A Connecting the Tributary T1 Interfaces To connect the balanced T1 interface (RJ-45 connector) • Connect the RJ-45 connector of the cable to the T1 port. Connecting the Uplink To connect a fiber optic uplink 1. Clean the optical connectors using an approved solvent, and dry thoroughly using optical tissue. 2.
MT1000A Installation and Operation Manual Quick Start Guide Connecting the Power Warning Before switching ON this unit and before connecting or disconnecting any other cable, the protective earth terminals of this instrument must be connected to the protective ground conductor of the mains (AC or DC) power cord. If you are using an extension cord (power cable) make sure it is grounded as well.
Contents Chapter 1. Introduction 1.1 Overview..................................................................................................................... 1-1 General ................................................................................................................................ 1-1 Features................................................................................................................................ 1-1 Application ...................................................
Table of Contents Setting the Terminal Communication Parameters .................................................................. 4-1 Entering the Terminal Session................................................................................................4-2 4.3 Monitoring the System ................................................................................................. 4-4 Monitoring the Status of the Local System ............................................................................
Chapter 1 Introduction 1.1 Overview General MT1000A is a second-order multiplexer that combines four T1 (1.544 Mbps) tributary data streams into a single fiber optic link. The fiber optic interface provides a secure link in hazardous or hostile environments, increases the maximum connection range, and achieves immunity against electrical interference and protection against the harmful effects of ground loops.
MT1000A Installation and Operation Manual Chapter 1 Introduction Application The following diagram illustrates a typical MT1000A configuration: Mux Mux T1 T1 Fiber Link T1 T1 T1 Video Conferencing T1 Video Conferencing Router (Optional) Backup Fiber Link T1 T1 Router PBX PBX ASCII terminal linked to supervisory port ASCII terminal linked to supervisory port Figure 1-1 Typical MT1000A Application 1.
MT1000A Installation and Operation Manual 1.3 Chapter 1 Introduction Functional Description MT1000A contains the following printed circuit boards: • One main circuit board that includes four tributary interfaces • One or two fiber optic interface boards (A and B) • One or two power supplies (A and B): AC/48 VDC wide-range power supply or 24VDC power supply.
MT1000A Installation and Operation Manual Chapter 1 Introduction Table 1-1 Fiber Optic Interface Characteristics Wavelength Fiber Type [nm] [µm] 850 Transmitter Type Typical Output Power [dBm] Receiver Typical Max. Connector Sensitivity Range Type [dBm] [km miles] 62.5/125 multimode Laser (VCSEL) -15 -34 4.5 2.8 ST, SC, FC/PC 1310 9/125 single mode Laser -12 -34 47 29.2 ST, SC 1310 9/125 single mode Laser [long haul] -2 -34 72 44.
MT1000A Installation and Operation Manual Chapter 1 Introduction Line coding is B8ZS or AMI. The nominal balanced interface transmit level is ±3.0 V. The line attenuation is up to 12 dB, and each T1 signal is processed by an adaptive equalizer that compensates for various cable lengths to ensure optimal performance. Phase Locked Loops (PLL) are used to recover the clock signals, and the resulting jitter performance complies with the requirements of ITU-T Rec. G.824.
MT1000A Installation and Operation Manual Chapter 1 Introduction Front panel indicators display each alarm condition. In addition, a dedicated connector is used to provide major and minor alarm indications, by means of dry contacts. The major alarm is activated in the following cases: • MT1000A is not powered, or total power supply failure (e.g., when two power supplies are installed, failure of both supplies). • Loss of fiber optic input signals, or loss of fiber optic frame synchronization.
MT1000A Installation and Operation Manual Chapter 1 Introduction When two power supplies are installed, they share the load; in case one of the supplies fails or its input power is disconnected, the other power supply continues providing power to MT1000A. 1.4 Technical Specifications Fiber Optic Interface Characteristics Applicable Standards ITU-T Rec. G.
MT1000A Installation and Operation Manual Chapter 1 Introduction CONTROL DTE Supervisory Port (Optional) Interface V.24/RS-232, asynchronous DTE interface Connector 9-pin D-type female connector Data Rate 9.6, 19.2, 38.4, 57.6 and 115.
MT1000A Installation and Operation Manual Chapter 1 Introduction Environment Operating Temperature 0° to 50°C (32° to 122°F) Relative Humidity Up to 90%, non-condensing Technical Specifications 1-9
Chapter 1 Introduction 1-10 Technical Specifications MT1000A Installation and Operation Manual
Chapter 2 Installation and Setup 2.1 Introduction MT1000A is delivered completely assembled. It is designed for operation as a desktop unit or for mounting in a 19-inch rack. For instructions of rack mounting, refer to the Rack Mounting Kit for 19 inch Racks guide that comes with the RM kit. Mechanical and electrical installation procedures for MT1000A are provided in the following sections. After installing the unit, refer to Chapter 3 for operating instructions and system configuration procedures.
Chapter 2 Installation and Setup MT1000A Installation and Operation Manual Fiber Optic Link Connections Each fiber optic link interface is terminated in two ST, SC, or FC-PC connectors, in accordance with order. The maximum allowable attenuation depends on the interface option ordered (refer to Table 1-1). When working with the WDM option, only one fiber optic cable per link should be connected.
MT1000A Installation and Operation Manual 2.5 Chapter 2 Installation and Setup Installation and Setup To install MT1000A: 1. Set the internal switches. 2. Connect MT1000A’s various interfaces in the order listed here. Warning This module may include Class A or Class 1 lasers. For your safety: • Do not look directly into the optical connectors while the module is operating. Remember that the MT1000A starts operating as soon as it is powered. • Do not attempt to adjust the laser drive current.
Chapter 2 Installation and Setup Warning MT1000A Installation and Operation Manual Access to the inside of the equipment is permitted only to qualified and authorized service personnel. To avoid accidental electric shock, always disconnect the unit from the power line and from all the cables before removing the cover. Dangerous high voltages are present inside the MT1000A when it is connected to power and/or to the links.
MT1000A Installation and Operation Manual LINK B INTERFACE BOARD LINK A INTERFACE BOARD SW3 OFF ON OFF ALARMS MASK CH1 CH2 CH3 CH4 ALARMS MASK Chapter 2 Installation and Setup ON Figure 2-1 MT1000A Main Board, Internal Settings Table 2-1.
MT1000A Installation and Operation Manual Chapter 2 Installation and Setup Closing the MT1000A Cover After completing the internal settings, replace the cover on the unit. To close the cover: 1. Place the top cover on the unit. 2. Insert the screw on both side panels. Note 3. Insert the eight screws on the top panel Insert the original cover screws in their positions and tighten carefully. Do not use excessive force. 2.
MT1000A Installation and Operation Manual Chapter 2 Installation and Setup To connect the fiber optic links: 1. Before connecting, clean the optical connectors using an approved solvent and dry thoroughly using optical tissue. 2. For each fiber optic link interface (A and B), connect two optical cables to the two optical connectors designated TX (transmit output) and RX (receive input) of the appropriate interface.
Chapter 2 Installation and Setup Warning MT1000A Installation and Operation Manual Before switching on this instrument, the protective earth terminals of the instrument must be connected to the protective ground conductor of the power cord. The power plug may only be inserted in a power outlet provided with a protective earth contact. The protective action must not be negated by the use of an extension cord (power cable) without a protective conductor (grounding).
Chapter 3 Operation 3.1 General In this chapter you will find detailed instructions for operating the MT1000A. The information presented in this chapter includes a description of the MT1000A front panel controls, and operating procedures (turning on, front-panel indications, and turning off). 3.2 Turning MT1000A On To turn on an MT1000A unit with a single power supply: 1. Connect the power cable to the power connector on the rear panel of the MT1000A. 2.
MT1000A Installation and Operation Manual Chapter 3 Operation Figure 3-1 MT1000A Front Panel Table 3-1 MT1000A Controls, Connectors and Indicators NO Control or Indicator Function 1 PWR A indicator ON (green) – Power supply A is turned on and is operating normally. ON (red) – Power supply A is turned on and a malfunction has been detected or is not been turned on. In this case, MT1000A continues to operate normally using power supply B (when installed).
MT1000A Installation and Operation Manual Chapter 3 Operation Table 3-1. MT1000A Controls, Connectors and Indicators (Cont.) NO Control or Indicator Function 15 AIS CH1 indicator ON – AIS signal is output by the corresponding tributary interface. 16 AIS CH2 indicator 17 AIS CH3 indicator 18 AIS CH4 indicator 19 MNG-ETH connector Connection to the optional management Ethernet interface. 19A MNG-ETH ACT indicator ON – Data is being transferred on the Ethernet link.
Chapter 3 Operation 3-4 Turning MT1000A Off MT1000A Installation and Operation Manual
Chapter 4 Configuration 4.1 Introduction The use of a terminal is optional for configuration, monitoring and maintenance operations. Terminal Management Modes The MT1000A provides the following terminal management modes: • Monitor – A supervisory ASCII ANSI terminal or a PC emulating an ASCII ANSI terminal connected directly to the MT1000A CONTROL port. • Ethernet – A PC running terminal emulation software or a management workstation, connected to the MT1000A via an Ethernet cable.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A automatically detects and adapts itself to terminal baud rates of 9,600, 19,200, 38,400, 57,600 and 115,200 bps. After detecting the correct baud rate, the User name prompt is displayed, and the new baud rate is saved in the divide. If the autodetection fails, the MT1000A CONTROL port uses the last baud rate that was saved in the device. The MT1000A login screen (see Figure 4-1) is displayed.
MT1000A Installation and Operation Manual Chapter 4 Configuration Main Menu 1. Configuration 2. Monitoring 1. Total Alarms 2. System Monitoring 1. Local System Status 2. Remote System Status 3. Local System Alarms 4. Remote System Alarms 5. System Log File 6. Clear Log File 3. Physical Port Monitoring 1. Local Physical Port Status 1. Management Ethernet 2. Up-Link Status 3. Channels Status 2. Remote Physical Port Status 1. Management Ethernet 2. Up-Link Status 3. Channels Status 3.
MT1000A Installation and Operation Manual Chapter 4 Configuration 4.3 Monitoring the System You can monitor the following aspects of the MT1000A system: • Local system status • Remote system status To access the monitoring options: 1. From the Main Menu, choose Monitoring. The Monitoring menu (Figure 4-4) is displayed. The Total Alarms option displays the total number of alarms that are currently activated. MT1000A Monitoring 1. Total Alarms 2. System Monitoring 3.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A System Monitoring 1. 2. 3. 4. 5. 6. Local System Status Remote System Status Local System Alarms Remote System Alarms System Log File Clear Log File > > [ ] [ ] [] > > Please select item <1 to 6> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-5.
MT1000A Installation and Operation Manual Chapter 4 Configuration Table 4-1. Local System Status Values Field Description SW Version Version number of the installed software. HW Version Hardware version number. BOOT Version The software boot version and the boot manager version installed on the device. Active link Identifies the currently active link. Redundancy status The redundancy state of the system: • AUTO • MANUAL • OFF.
MT1000A Installation and Operation Manual Chapter 4 Configuration Monitoring the Status of the Remote System To monitor the status of the remote system: • From the System menu, choose Remote System Status. The Remote System Status screen (Figure 4-7) is displayed. The fields in this screen have the same meaning as those in the Local System Status screen, described in Table 4-1.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Physical Port Monitoring 1. 2. 3. 4. Local Physical Port Status Remote Physical Port Status Local Physical Port Alarms Remote Physical Port Alarms > > [] > [] > > Please select item <1 to 4> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-8. Physical Port Monitoring Menu The Remote Physical Port Status and Remote Physical Port Alarms options are available only when the MT1000A is connected to a remote device. 2.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Management Ethernet Status Link Integrity (No integrity) > ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-10. Ethernet Status Screen The Link Integrity can be one of the following: • OK—The Ethernet cable has integrity • No integrity—The Ethernet cable is not connected or some other problem exists.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Channel Port Status Status Line code Balance mode (No alarm) (B8ZS) (Balance) 1. Channel Num > (1) > Please select item <1 to 1> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-12. Channel Port Status Screen 4.5 Working with the System Log File Displaying the System Log File To display the system log file: • From the System Monitoring menu (Figure 4-5), choose System Log File.
MT1000A Installation and Operation Manual Chapter 4 Configuration Clearing the System Log File To remove all entries from the log file: 1. From the System Monitoring menu (Figure 4-5), choose Clear Log File. A confirmation message appears. 2. Press Y to erase the log file. 4.6 Alarms MT1000A detects fault conditions and initiates alarms and events to alert the user: • Alarms (major and minor) have two statuses: ON and OFF.
MT1000A Installation and Operation Manual Chapter 4 Configuration Displaying Physical Port Alarms To display the physical port alarms: 1. From the Physical Port Monitoring menu (Figure 4-8), choose Local Physical Port Alarms or Remote Physical Port Alarms. The Physical Port Alarms menu (Figure 4-15) for the local or remote MT1000A device is displayed. MT1000A Physical Port Alarms 1. Up link alarms 2. Port Alarms [ ] [ ] > Please select item <1 to 2> ESC-prev.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Port Alarms Source Local P-2 Local P-3 Name Rx AIS Signal Loss Num 23 21 Severity MINOR MAJOR Status ON ON > ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-17. Port Alarms Screen The Port Alarms screen only displays alarms that are currently triggered. Alarms that are currently in the OFF status (not activated) are not displayed. The MT1000A port alarms are described in Chapter 5. 4.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Configuration 1. System configuration 2. Physical ports configuration > > > Please select item <1 to 2> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-18 Configuration Menu 2. Choose System Configuration. The System Configuration menu (Figure 4-19) is displayed. MT1000A System configuration 1. 2. 3. 4. 5.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Local Redundancy 1. Force Link 2. Redundancy Mode > (Link A) (Auto) Please select item <1 to 2> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-21. Local Redundancy Menu 5. Choose the link for which you want to set redundancy. Choose Force Link to toggle the selected Main Link between Link A and Link B. 6. Choose Redundancy Mode to set the mode to use. The Redundancy Mode menu (Figure 4-22) is displayed.
MT1000A Installation and Operation Manual Chapter 4 Configuration Setting the Device Information Each MT1000A unit can be configured to hold information about the unit, such as its location and a name to easily identify the unit on the network. To set device information: 1. From the System Configuration menu (Figure 4-19), choose Management. The Management menu (Figure 4-23) is displayed. MT1000A Management 1. 2. 3. 4.
MT1000A Installation and Operation Manual Chapter 4 Configuration Setting the network parameters When you integrate the MT1000A into your network, you will need to set the network parameters of the MT1000A. To set the network parameters: 1. From the Management menu (Figure 4-23), choose Host IP. The Host IP menu (Figure 4-25) is displayed. MT1000A Host IP 1. 2. 3. 4. 5. Host IP List > Default Gateway Read Community Write Community Trap Community ... ... ... ... (172.17.161.
MT1000A Installation and Operation Manual Chapter 4 Configuration Setting up the Manager List By default, any remote management terminal is allowed to change the configuration of the MT1000A. You may enhance the security of the site by limiting remote management to specific management terminals or nodes. The Manager List lists the network nodes from which management may take place. To define the manager list: 1. From the Management menu (Figure 4-23), choose Manager List.
MT1000A Installation and Operation Manual Chapter 4 Configuration 2. Choose the method to use for management access: SNMP (the management terminal connects to the MT1000A via SNMP connection) Telnet (the management terminal connects to the MT1000A via Telnet connection) Web (the management terminal connects to the MT1000A via Web connection) The menu shown in the following figure is displayed. The title of the menu indicates which management access option is being configured.
MT1000A Installation and Operation Manual Chapter 4 Configuration 2. Choose Change Access. The Change Access menu (Figure 4-31) is displayed. MT1000A Change Access 1. Change User Name 2. Change Password > Please select item <1 to 2> ... (user) ... () ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-31. Change Access Menu 3. To change the user name, choose Change User Name and then enter the new user name. 4. To change the password, choose Change Password and then enter the new password.
MT1000A Installation and Operation Manual Chapter 4 Configuration Resetting the Factory Defaults You can reset all of the local MT1000A configuration parameters to their default settings, or you can reset all parameters except for the management settings (IP addresses) To reset parameters to the factory defaults: 1. From the System Configuration menu (Figure 4-19), choose Local Factory Default. The Factory Default menu (Figure 4-33) is displayed. MT1000A Factory Default 1. All 2.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Physical ports configuration 1. Local Physical Ports Configuration 2. Remote Physical Ports Configuration > > > Please select item <1 to 2> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-34. Physical Ports Configuration Menu The Remote Physical Ports Configuration option is shown only when a remote MT1000A device is connected. 2. Choose Local Physical Ports Configuration or Remote Physical Ports Configuration.
MT1000A Installation and Operation Manual Chapter 4 Configuration Full (Full-duplex mode) Half (Half-duplex mode). 5. Choose Ethernet alarm mask to toggle the Ethernet alarm on or off. Configuring the Channels To configure the channels: 1. From the Local/Remote Physical Ports Configuration menu (Figure 4-35), choose Channels Configuration. The Channels Configuration screen (Figure 4-37) is displayed. MT1000A Channels Configuration 1. 2. 3. 4. 5.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A Up-link Configuration 1. 2. 3. 4. Link Link Link Link A A B B name alarm mask name alarm mask ... ( ) (Off) ... ( ) (Off) > Please select item <1 to 4> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-38. Up-Link Configuration Screen 2. If you would like to specify a name to easily identify Link A, choose Link A name and then enter a name for the link. 3. Choose Link A alarm mask to toggle the alarm for Link A on or off.
MT1000A Installation and Operation Manual Chapter 4 Configuration 2. Choose Local Device Loops. The Local Device Loops Menu (Figure 4-40) is displayed. MT1000A Local Device Loops 1. Loops Setting [] 2. Uplink LLB timeout (min) > ... (5) > Please select item <1 to 2> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-40. Local Device Loops Menu 3. Choose Uplink LLB Timeout and then enter the timeout in minutes. The value you specify is the duration of the E2 LLB loopback test.
MT1000A Installation and Operation Manual Chapter 4 Configuration 2. Highlight the Loop status field of the channel you want to change. 3. Enter the loopback status you want to set: No loop—No loopback on the channel LLB—Local loopback on the channel or uplink RLB—Remote loopback on the channel. See Chapter 5 for definitions of local channel and uplink loopbacks in the remote MT1000A. The loopback test begins running immediately after a loopback has been set.
MT1000A Installation and Operation Manual Chapter 4 Configuration 4.10 Viewing Hardware and Software Updates To view the last MT1000A hardware and software updates: 1. From the Main Menu (Figure 4-2), choose Monitoring. The Monitoring menu (Figure 4-4) is displayed. 2. Choose System Monitoring. The System Monitoring menu (Figure 4-5) is displayed. 3. Choose Local System Status to display the status of the local MT1000A, or choose Remote System Status to display the status of the remote MT1000A.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A S/W & File Transfer 1. Via TFTP 2. Via X-Modem > Please select item <1 to 2> ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-43. S/W & File Transfer Menu 3. Choose Via TFTP. The Via TFTP menu (Figure 4-44) is displayed. Note The Via TFTP option is available only if the local MT1000A has been assigned an IP address. MT1000A Via TFTP Transfer Status Transfer Error 1. TFTP File Name 2. TFTP Server IP 3.
MT1000A Installation and Operation Manual Chapter 4 Configuration Downloading Software using the X-Modem Protocol To download a new software version via X-Modem: 1. Open the S/W & File Transfer menu (Figure 4-43). 2. Choose Via X-Modem. The download process begins as soon as the remote computer starts the upload process. Note that you need to run an X-Modem application on the remote computer to invoke the upload. 4.12 Viewing file and file system information To view information about the file system: 1.
MT1000A Installation and Operation Manual Chapter 4 Configuration MT1000A SW Files Software active version Software active partition Code size Date Software backup version Software backup partition Code size Date Boot version Boot mng version 1.00 0 190 01-01-02 0.00n00 1 0 0-0-0 2.20 4.00 > ESC-prev.menu; !-main menu; &-exit 1 user(s) Figure 4-46. SW Files Screen To change the software boot partition: 1. Open the File System menu (Figure 4-45). 2.
Chapter 5 Testing and Diagnostics 5.1 Introduction This chapter includes a description of the MT1000A diagnostic tests and troubleshooting procedures. 5.2 Troubleshooting In case a problem occurs, check the displayed indications and refer to Section 3-2 and Table 3-1 for their interpretation. Identify the trouble symptoms and perform the actions listed under Corrective Measures in the order given in Table 5-1, until the problem is corrected.
Chapter 5 Testing and Diagnostics MT1000A Installation and Operation Manual Table 5-1. Troubleshooting Chart (Cont.) Trouble Symptoms Probable Cause Corrective Measures The SYNC LOSS indicator of the fiber optic link lights. External problem Activate the local loopback on the MT1000A. Check that the SYNC LOSS and AIS indicators of the fiber optic link in use turn OFF.
MT1000A Installation and Operation Manual 5.3 Chapter 5 Testing and Diagnostics List of Alarms and Events The MT1000A alarms are described in Table 5-2. Table 5-2. MT1000A System Alarms Message on terminal Description Severity CDP fail A failure has occurred in the CDP. Major FLASH problem A problem occurred in the device FLASH device. Could not save user configuration. Major PS1 FAIL Power supply A has failed. Major PS2 FAIL Power supply B has failed.
MT1000A Installation and Operation Manual Chapter 5 Testing and Diagnostics The MT1000A events are described in Table 5-4. Table 5-4. MT1000A Events Event Description BUFFER OVERFLOW The log file overran the last events. LOGIN SWITCH ON User changed access name. PASSWORD SWITCH ON User changes access password. SW DOWNLOAD FAIL Software download failed. SW DOWNLOAD OFF Software download process finished. SW DOWNLOAD ON Software download is in process.
MT1000A Installation and Operation Manual Chapter 5 Testing and Diagnostics Local Loopbacks in the MT1000A You can set two types of local loopback connections in the MT1000A unit: • T1 local, which is set for each T1 interface separately from a terminal. • Fiber optic link local, which can be set from a terminal. T1 Local Loopback in the MT1000A The T1 local loopback returns the T1 transmit signal to the output of the receive path. Simultaneously, an unframed all-ones signal is sent to the MUX.
Chapter 5 Testing and Diagnostics MT1000A Installation and Operation Manual Fiber Optic Link Local Loopback in the MT1000A The fiber optic local loopback returns the transmit signal of the active fiber optic link interface to the input of the receive path. Simultaneously, the local MT1000A sends an unframed all-ones signal to the fiber optic link. Figure 5-2 shows the fiber optic link local loopback connection.
MT1000A Installation and Operation Manual Chapter 5 Testing and Diagnostics Remote Loopbacks in the MT1000A You can set two types of remote loopback connections in the MT1000A unit: • T1 remote, which is set for each T1 interface separately, from the terminal. • Fiber optic link remote, which can be set from the terminal. T1 Remote Loopback in the MT1000A The T1 remote loopback returns the transmitted Demuxed T1 to the receiver Mux.
Chapter 5 Testing and Diagnostics MT1000A Installation and Operation Manual Fiber Optic Remote Loopback in the MT1000A The fiber optic remote loopback returns the received signal of the active fiber optic link interface to the input of the transmit path. Simultaneously, the remote MT1000A sends an unframed all-ones signal to the input of the Demux. Figure 5-4 shows the fiber optic remote loopback connection. This test checks the operation of the local MT1000A and the connection to the remote MT1000A.
Appendix A Interface Specifications A.1 Tributary Connectors Each tributary interface has one RJ-45 eight-pin connector. Connector wiring is listed in Table A-1. Table A-1.
MT1000A Installation and Operation Manual Appendix A Interface Specifications A.2 Alarm Connector The MT1000A ALARM connector is a 9-pin female connector, which includes the contacts of the major and minor alarm relays. Figure A-1 shows the pin functions. The relay positions are shown in the non-energized (alarm active) state. ALARM CONNECTOR MINOR ALARM RELAY 1 2 6 MAJOR ALARM RELAY 4 5 9 Figure A-1.
MT1000A Installation and Operation Manual Appendix A Interface Specifications A.3 Control Connector The optional MT1000A supervisory port has a standard RS-232 DTE interface. The physical interface is a 9-pin female connector, designated CONTROL. Connector wiring is given in Table A-2. Table A-2.
Appendix A Interface Specifications MT1000A Installation and Operation Manual A.5 Power Connectors The power connector used for the AC/DC power supply is a standard square 3-prong female connector. For information on the DC power connector, refer to the two supplements at the end of this manual: DC Power Supply Connection - Terminal Block Connector Supplement and the DC Power Supply Connection - AC/DC Adaptor (AD) Plug Supplement.
Appendix B MT1000A MIBs A MIB (Management Information Base) is a database of managed objects. The MIB contains the data regarding the network elements being controlled and monitored. Each characteristic of the element to manage is defined as an object in the MIB. The MIB is a hierarchical tree structure that acts as the repository for defined objects.
Appendix B MT1000A MIBs B-2 MT1000A Installation and Operation Manual
Index —A— AC/DC connections, 2-8 AIS, 1-5 alarm connector specifications, 1-8 alarm relays connector, 2-7 alarms, 1-5, 4-11 connector, A-2 physical port, 4-12 port, 5-3 system, 4-11, 5-3 Up-Link, 5-3 applications, 1-2 automatic switching, 1-4 —B— Baud Rate menu, 4-20 boards, 1-3 —C— Change Access menu, 4-20 changing software boot partition, 4-30 channel port Channel Port Status screen, 4-9 monitoring the status, 4-9 channels Channels Configuration screen, 4-23 configuring, 4-23 up-links, 4-23 circui
MT1000A Installation and Operation Manual Index —F— factory defaults Factory Default menu, 4-21 resetting, 4-21 features, 1-1 fiber optic connections, 2-2, 2-7 interface, 1-3 local loopback, 5-6 redundancy, 1-4 remote loopback, 5-8 specifications, 1-7 file system File System menu, 4-29 viewing information, 4-29 File Utilities menu, 4-27 front panel clearance, 2-2 connectors, 3-1 controls, 3-1 indicators, 3-1 —G— grounding, 2-7 connection, 2-7 —H— hardware viewing updates, 4-27 setting, 4-25 sett
MT1000A Installation and Operation Manual Remote Device Loops, 4-25, 4-26 Remote Physical Port Status, 4-8 S/W & File Transfer, 4-27 System Configuration, 4-14 System Monitoring, 4-4, 4-27 Telnet, 4-19 Via TFTP, 4-28 monitoring, 1-6 channel port status, 4-9 Ethernet port status, 4-8 local system status, 4-5 physical port, 4-4 physical ports, 4-7 remote system status, 4-7 system, 4-4 up-link status, 4-9 Monitoring menu, 4-4, 4-27 —N— network parameters setting, 4-17 normal indications, 3-3 —O— operating,
MT1000A Installation and Operation Manual Index setup, 2-1, 2-3 site prerequisites, 2-1 requirements, 2-1 software boot partition, 4-30 downloading, 4-27 downloading using X-Modem protocol, 4-29 downloading via TFTP protocol, 4-27 viewing updates, 4-27 specifications, 1-7 alarm connector, 1-8 control DTE supervisory port, 1-8 environment, 1-9 fiber optic, 1-7 indicators, 1-7 interface, A-1 management port, 1-8 physical characteristics, 1-8 power supply, 1-8 T1 tributary interface, 1-7 status —T— T1
DC Power Supply Connection – Terminal Block Connector Note: Ignore this supplement if the unit is AC-powered. Certain DC-powered units are equipped with a plastic 3-pin VDC-IN power input connector, located on the unit rear panel. Different variations of the connector are shown in Figure 1. All are functionally identical. Supplied with such units is a kit including a mating Terminal Block (TB) type connector plug for attaching to your power supply cable.
Note: Certain TB plugs are equipped with captive screws for securing the assembled cable’s TB plug to the unit’s VDC-IN connector (C and E types only). To secure the plug, tighten the two screws on the plug into the corresponding holes on the sides of the input connector as shown in Figure 3. Captive screws Figure 3. TB Plug with Captive Screws (optional) DC Power Supply Wire Voltage Polarity Refer to Figure 4 for proper mapping of the power supply wire leads to the TB plug’s three terminals.