® ® BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial or residential environment. CUSTOMER Order toll-free in the U.S. 24 hours, 7 A.M.
T1/E1 LINK EXTENDERS CE NOTICE We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity.
T1/E1 LINK EXTENDERS If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
T1/E1 LINK EXTENDERS COMPLIANCE EMC • FCC Part 15, Class A • EN55022, Class A • EN55024 SAFETY • UL 60950-1/CSA C22.2 N0.
T1/E1 LINK EXTENDERS SAFETY WHEN WORKING WITH ELECTRICITY • This device contains no user serviceable parts. The equipment shall be returned to Black Box for repairs, or repaired by qualified service personnel. WARNING • The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator.
T1/E1 LINK EXTENDERS CONTENTS CE Notice .................................................................................................... 2 Radio and TV Interference .......................................................................... 2 FCC Part 68 ................................................................................................. 2 Industry Canada Notice ............................................................................... 3 Compliance.......................................
T1/E1 LINK EXTENDERS A.10 Line Interface ....................................................................................15 A.11 Line Physical Connection .................................................................15 B. Factory Default Dip Switch Configuration ............................................... 16 B.1 Switch S1 - Factory Default configuration .......................................16 B.2 Switch S2 - Factory Default Configuration ......................................
T1/E1 LINK EXTENDERS 1. General Information Thank you for your purchase of this Black Box product. If any questions arise during installation or use of the unit, contact Black Box Tech Support at (724) 746-5500. 1.1 Features • Easy-to-install T1/E1 Extenders—no configuration required • Data rates up to 2.048 Mbps in 64-kbps intervals • Plug ‘n’ Play for easy installations • LED indicators for Power, Ethernet Link, and Frame • CE marked 1.
T1/E1 LINK EXTENDERS 2. Installation Because the T1/E1 Extenders require no configuration, they can be installed quickly. Installation consists of the following: • Connect the power plug (refer to section 2.1, “Connecting Power” on page 10). • Connect the line port (refer to section 2.3, “Connecting the Line Port” on page 11) Note See Figure 1 and Figure 2 for the rear-panel connectors locations. • Connect the T1/E1 port (refer to section 2.4, “Connecting the Circuit Interface” on page 11).
T1/E1 LINK EXTENDERS 2.1 Connecting Power CAUTION The external AC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. Ensure that the AC power cable meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground. Your T1/E1 Extender comes with an external AC adaptor with a detachable power cord.
T1/E1 LINK EXTENDERS 2.3 Connecting the Line Port CAUTION The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. Follow the steps below to connect the line port: 1. Obtain a single-twisted pair cable with an RJ-45 plug connector at each end. 2. Plug one end of the cable into the RJ-45 socket (labeled Line) on the T1/E1 Extender . 3.
T1/E1 LINK EXTENDERS 3. Operation Once the T1/E1 Extenders are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors. 3.1 Front Panel LED Status Monitors Models MT196A-E1 and MT195A-T1 feature three front-panel LEDs that monitor power, Ethernet signals, and the CopperLink connection. Figure 4 shows the front panel location of each LED. Table 1 describes the LED functions.
T1/E1 LINK EXTENDERS 3.2 Configuration and Dip Switches The T1/E1 Extenders are Plug ‘n’ Play enabled and do not require any configuration by the user. Note The user should NOT change any of the dip switches except for S1-7 (if necessary). If the user changes the position of any of the dip switches (except for S1-7), it will affect the operation of the unit. Refer to Appendix B. on page 16 for the factory default dip switch configuration. 3.2.
T1/E1 LINK EXTENDERS A. Specifications A.1 Circuit Rates • Model MT196A-E1 - 2.048 Mbps • Model MT195A-T1 - 1.544 Mbps A.2 Circuit Interface • E1 (Model MT196A-E1) presents G.703/G.704 interface. Either 75 Ohms (unbalanced) or 120 Ohms (balanced). Pins 1 & 2 are Receive. Pins 4 & 5 are transmit. • T1 (Model MT195A-T1) present T1 interface. Pins 1 & 2 are Receive. Pins 4 & 5 are Transmit. A.3 Circuit Defaults • E1 Line Coding = HDB3.
T1/E1 LINK EXTENDERS A.7 Environmental • Temperature: 32–122°F (0–50°C) • Relative Humidity: 5–95%, non-condensing • Altitude: 0–15,000 ft (0–4,572 m) A.8 Transmission Line • Single Twisted Pair A.9 Line Coding • TC-PAM (Trellis Coded Pulse Amplitude Modulation) A.10 Line Interface • Transformer coupled, 2500 VRMS isolation A.
T1/E1 LINK EXTENDERS B. Factory Default Dip Switch Configuration Note This information is provided for informational purposes only. These settings should not be changed other than by instructions from Black Box Support, lest the unit be rendered inoperable. B.
T1/E1 LINK EXTENDERS Notes ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ______________________________
T1/E1 LINK EXTENDERS Notes ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ______________________________
T1/E1 LINK EXTENDERS Notes ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ______________________________
® BLACK BOX ® NETWORK SERVICES © Copyright 2007. Black Box Corporation. All rights reserved.