July 2005 LBH150A(AE) -H, -P LBH240A(AE) -H, -P LBH600A(AE) -H, -P Heavy Duty Edge Switches © Copyright 2005. Black Box Corporation. All rights reserved. 1000 PARK DRIVE • LAWRENCE, PA 15055-1018 • 724-746-5500 • FAX 724-746-0746 CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M.
Black Box Heavy Duty Edge Switches ® Installation and User Guide (07/05) BLACK BOX Series Heavy Duty Edge Switches Installation and User Guide Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important: The LBHXXX-Series 10/100 Mb/s Edge Switches contains no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) Contacting Black Box Corporation Please use these mailing address and phone and fax numbers: Black Box Corporation 1000 Park Drive Pittsburgh, PA 15055 Phone: (724) 746-5500 Fax: (724) 746-0746 E-mail: info@blackbox.
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) FEDERAL COMMUNICATIONS COMMISSION AND CANADIAN DEPARTMENT OF COMMUNICATIONS RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication.
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Black Box Heavy Duty Edge Switches 5. Installation and User Guide (07/05) El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean reconnendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recommendado por el fabricante. 8.
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) 12. Precaución debe ser tomada de mal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14.
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) Certification Notice for Equipment Used in Canada The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications-network protective, operation, and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Black Box Heavy Duty Edge Switches TABLE OF CONTENTS Installation and User Guide (07/05) Page 1.0 SPECIFICATIONS (HEAVY-DUTY EDGE SWITCHES) .............. 1 1.1 Technical Specifications ..................................................................... 1 1.2 Summary of models and descriptions ................................................... 10 2.0 INTRODUCTION ............................................................................... 12 2.1 Inspecting the Package and the Product................
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) 3.6 DC Power Terminals: “+”, “-”, gnd......................................................... 46 3.7 LBHXXXA(E)-H and -P Series, DC-powered,................................. 47 3.8 Connecting Ethernet Media ............................................................... 48 3.8.1 Connecting Twisted Pair............................................................ 50 3.8.2 Connecting Fiber Optic ST-type, “twist-lock”.......................
Black Box Heavy Duty Edge Switches Installation and User Guide (07/05) Return Material Authorization (RMA) Procedure ............................. 65 5.3 Revisions Rev A 06/05: Initial release of this user manual for Heavy Duty Edge Switches Black Box. reserves the right to change specifications, performance characteristics and/or model offerings without notice.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 1.0 SPECIFICATIONS (Heavy-Duty Edge Switches) 1.1 Technical Specifications Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Latency (not including packet time): 100 to 10 Mbps: 5µs 10 to 100Mbps: 15µs Path Delay Value: 50 BT on all ports LLL(Link-Loss-Learn): Factory default is activated on port 1 and 2 (allow to flush the internal address buffer , and qualify to use STP/RSTP for faster recovery in ring topology) Maximum Ethernet Segment (or Domain) Lengths 2 10BASE-T (Unshielded twisted pair) 100BASE-TX (CAT 5 UTP) - 100 m (328 ft) - 100 m (328 ft) 100BA
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Operating Environment LBHXXXA(E): 32ºF to 104ºF (0ºC to 40ºC) LBHXXXA(E)-H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL). -40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests. LBHXXXA(E)-P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL). -58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.
Black Box® Heavy Duty Edge Switches Packaging: Installation and User Guide(07/05) Enclosure: Rugged sheet metal (Steel). Dimensions of the Switch unit: 3.7 in H x 3.0 in W x 1.7 in D (9.4 cm x 7.6 cm x 4.3 cm) Weight: all models: 13 oz. (370g); Power supply, A, and AE: 5.8 oz (165g) A–H, and AE-H: 5.8 oz (165g) A–P, and AE-P: 7.9 oz (225g) Cooling Method: Convection on the office model.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) POWER SUPPLY These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to 500mA).When connected to a 48V centralized DC source, these products shall be provided with a Listed 5 A DC fuse in the supply circuit.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Office Models Ratings (0 to 40°C) North America (A) models. Input: direct plug-in 95-125vac at 60 Hz. Output:12vdc, 1Amps International (AE) models. Input: 240vac at 50Hz with IEC 320 connector for the user supplied AC power cord. Output:12vdc, 1Amps Factory Floor Models (H) Ratings (-25 to 60°C) North America (A-H) models. Hardened, factory floor temperature rated.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) International (AE-P) models. Outdoor temperature rated. Input: IEC 320 connector on the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord. Output:12vdc, 2Amps. Note: LH1505-CK - For Hardened or Extreme -24VDC unit only for dual DC power (sold separately). See 3.6. Power Consumption: See Section 3.6. Note 1: the 12V DC jack can be used for dual source DC input using an AC adapter and the DC terminal block.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Fiber optic port: supports 100Base-FX with a “fiber flavor” choice of multimode SC, ST, LC or MTRJ or single mode SSC, SSCL, SST or SLC connectors.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method Agency Approvals and Standards Compliance: UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A. NEBS L3 and ETSI compliant. Hardened and Extreme models: IEEE 1613 Env.
Black Box® Heavy Duty Edge Switches 1.2 Installation and User Guide(07/05) Summary of models and descriptions Note: The LBH150, LBH240 and LBH600 model # consists of the base unit, for domestic power supply add A, for international power supply add AE, fiber interface xx and the dc power option yy. (see note for xx and yy) In three different temperatures range Standard, Hardened and Extreme. Standard for office and wiring closet (0 to 40C) using an external AC power supply.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Note: xx for fiber interface “SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km. “SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km. “SSCL”= 100Base-FX-SSCL: single-mode fiber optic with SC type connector, 40km. “ST” = 100Base-FX-ST: multi-mode fiber optic with ST type connector, 2km. “SST” = 100Base-FX-ST: single-mode fiber optic with ST type connector, 2km.
Black Box® Heavy Duty Edge Switches 2.0 Installation and User Guide(07/05) INTRODUCTION This section describes LBHXXX Series models, including appearance, features and typical applications. 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage which you believe occurred during shipment or delivery.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Remove the Black Box LBHXXX Series Edge Switches from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for specific return procedures. 2.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) built in, covers the full range of application environments, with regular (office), Hardened (factory floor), and Extreme-rated (outdoor) versions. Extra features for HeavyDuty(LBHXXX )and extended temperature operation ranges are included selectively in the Hardened factory-floor and Extreme-rated outdoor models. The breadth of models and flavor of fiber port types offers the best price-to-value ratio for each user and installation.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Black Box managed switches, running STP/RSTP, can often provide high availability Redundant LANs at economical cost. The Heavy-Duty LBHxxx-Series regular-package units are for office and indoor wiring closet environments. These are the economical base units in the LBHxxxA Switch family. An external AC power supply for either North America (-d, 115vac 60Hz) or international (-I, 230vac, 50Hz) is included.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Fig 2.2 b Fig 2.2b (LBH150A-SC) left with four10/100 RJ-45 and two fiber 100Mb The Regular Heavy-Duty LBHXXX Edge Switches models (as shown in Fig 2.2.a, b,) units are for office and wiring closet environments and use an external AC power supply. A ventilated metal case for convection cooling is featured. Ambient operating temperature is 0° to 40°C. Storage temperature rating is -40°to 85°C.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) The regular model LBHXXXA, includes Link-Loss-Learn, MDIX ports and the full range of fiber port options. The regular LBH150A/LBH240A model does not have options for Alarm and DC power The Hardened labeled Heavy-Duty LBHXXXA-H Edge Switches H units (shown in Fig 2.2c & d) are designed for factory floor/Industrial applications.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) The Heavy-Duty LBH150A-H/LBH240A-H Edge Switches, Hardened units are for factory floor applications. The LBHXXXA-H models are built with high-grade components and are constructed using special thermal techniques and a metal case for heavy duty Fig. 2.2.d Hardened LBH240A-H-ST industrial jobs. In addition to a Hardened AC power option and jack, terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) models for external AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C depending on the power source used. Storage temperature rating is –25°C to + 85°C. Fig 2.2e & f, Extreme model LBH240AP-ST LBH600A-P The Extreme labeled Heavy-Duty LBHXXXA(E)-P Edge Switches Extreme-rated units are for temperature un-controlled applications (-40 to 75°C), typically located outdoors.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) extended temperature components, and use similar thermal techniques as the LBHXXXA-H Hardened units. In addition to a Extreme-rated AC power option and jack, terminals for internal DC power choices at 8 to15V, 24V or -48V DC are included. When used outdoors, the LBHXXXA-P should be protected from rain. Mounting options include stand-alone panel-mounting, DIN-rail, or rack-mount tray. The LBHXXXA-P series (as shown in Fig. 2.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) All the Extreme and hardened models also come along with hardware operated Alarm terminal block for providing extra reliability to the unit. The Alarm feature allows the LBHXXX heavy duty users to be aware and to monitor any internal power failure. See section 44 for details. The front side of the unit has four/five twisted-pair 10/100Mb switch ports and one/two 100Mb fiber port.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) connected correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s are repeated on the front as 1 (port 1)…6 (port 6), whereas on the side as LA1…LA6 . There is another set of LEDs on the front for 10 or H and 100 or F, to indicate the data rate as well as a set to indicate duplex for ports 1 and 2 only. 10/100 indicates the speed for copper ports, whereas F/H indicates Full and Half duplex for fiber ports only.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) length and have the correct CRC, i.e. they are good packets. This eliminates propagation of bad packets, enabling all of the available bandwidth to be used for valid information. While other switching technologies such as "cut-through" or "express" impose minimal frame latency, they will also permit bad frames to propagate to the Ethernet network.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) (Many other switches have their packet buffer storage space divided evenly across all ports, resulting in a small, fixed number of packets to be stored per port. When the port buffer fills up, dropped packets result.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Another feature implemented in Heavy-Duty LBHXXX Edge Switches is a collision-based flow-control mechanism (when operating at half-duplex only). When the Switch detects that its free buffer queue space is low, the Switch prevents more frames from entering by forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 2.4 Features and Benefits Full 100Mb or 10 Mb switching services for high performance Ethernet Black Box Heavy-Duty LBHXXX Switches provide Fast Ethernet switching on all ports. They perform high speed filter/forward operations on the traffic, giving each port’s segment a full 100Mb (or 10 Mb) of bandwidth.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Installation is “Plug and Play”, operation is transparent to software The Black Box Heavy-Duty LBHXXX Switches operate as hardware switches, only forwarding those packets from each domain that are needed on the other domains. Internal address tables are self-learning, enabling users to change port connections or 10/100 domains without affecting operations. Two sets of LEDs for viewing status from any angle.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Qualified to use for temperature un-controlled “outdoor” application The Black Box LBHXXXA(E)-P Extreme rated versions of Edge Switches have an ambient temperature rating between –40ºC to +75ºC for DC models and qualify for temperature un-controlled “outdoor” application.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Hardware operated Alarm terminal block for LBHXXXA(E)-H and LBHXXXA(E)-P The Alarm contact option on LBHXXXA(E)-H and LBHXXXA(E)-P enables monitoring for internal power failure, and provides extra reliability to the hardened Switch Link-Loss-Learn feature for faster recovery in redundant managed network The LLL feature qualifies the Edge switches to actively work along with redundant network structure as a client switch and allow a fas
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) offered by Black Box Edge Switches provide convenient, economical, and reliable solutions as well as an active role on the managed redundant network setup for faster recovery. The compact Black Box Heavy-Duty LBHXXX assists fast expanding network requirements via providing edge support and reliability to the managed redundant network.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Example1. Supermarket application for LBHXXX- In this example, the supermarket required a Data Mining function to store all the transaction with an ongoing demand to expand the network. This need can be easily met using the economical Black Box LBHXXX Edge Switch.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) across large distances with multi- or single–mode fiber while securing the LAN from EMI and wire tapping. The LBHXXX’s six ports in a small, reliable metal enclosure provide an effective solution to for transferring real-time transactions from the store to the storage device in the control room.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Example 2: LBHXXXA(E)-H and LBH100AE In this industrial networking application, the new PLC units are deployed on a network expansion, and each PLC required one (or two for redundancy) Ethernet ports to carry status and control data to the control center. The LBHXXXA and LBH100A provide a good solution with their multiple options and hardened features.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) PLC PLC PLC Internet Router PLC PLC PLC PLC PLC 34 PLC PLC PLC
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Example 3: LBHXXXA(E)-P: In this example, the Black Box LBHXXXA(E)-P Extreme Edge Switches are deployed to serve as a secure corporate or transportation surveillance system. CCTV cameras may be spread out over many miles in temperature un-controlled locations and with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Interne Router CCTV CCTV CCTV 36 CCTV
Black Box® Heavy Duty Edge Switches 3.0 Installation and User Guide(07/05) INSTALLATION This section describes the installation of the Black Box Heavy-Duty LBHXXX Edge Switches, including location, mountings, power supply options and media connection. 3.1 Locating the Edge Switch Unit All the Heavy-Duty LBHXXX Switches operate in transparent half-and full-duplex mode.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) mounting the unit on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure mounting in any orientation. Installation of the Black Box Heavy-Duty LBHXXX Edge Switches is a simple procedure. The installation location is dependent upon the physical layout of the Ethernet network and associated cabling.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Switches and/or Media Edges may be placed on a tray, up to a maximum of 8 units. (The mounting spaces of the LH1505P-RACK are specific to the Black Box products and will not permit other models to be properly mounted).
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) beveled-top edge of the units permits the LEDs of each unit to be viewed for operational status, even when the units are very close together. 3.3 LH1505-RACK-1-9V and LH1505-RACK-2-9V for Rack Mounting Media Edges The LH1505-RACK-1-9V and LH1505-RACK-2-9V are other options for rack mounting the mix of Black Box 10Mbps and 100Mbps Edge Switches and Media Edges together in a 19” rack-mount tray.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) The side-view < here is an example of an installation of the model LH1505P-RACK, 19” rack-mount tray, holding a few LBHXXX, and LBH100A, each with their power input plugged into the built-in common AC power supply in the rear area of the tray. (AC PS units that come with the office models of the Edge Switch’s are not used). Because of the thicker size, only eight LBHXXX units can fit in one LH1505P-RACK.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) The metal DIN-Rail mounting hardware is optional and needs to be ordered as a separate item, e.g. Model #XXXXX. It comes with four screws to attach the bracket to the MC unit. The rail clip is spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal. The Black Box LBHXXX models with “HD” and “PD” have 24VDC power, and have the DINRail- bracket included and assembled with the unit at the factory. 3.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) The extended temperature (H and P) versions are used for heavy duty industrial applications. The 12V DC power input jack has a plug of 2.5mm, center +ve , with 6 ft. cord. All the AC power supply info detail is provided in Technical Specs Section 1.1. The Heavy-Duty LBHXXX are designed to be used with UL listed Class II power supplies.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 3.5 Powering the LBHXXXA(E)-H and LBHXXXA(E)-P (DC internal) with 12V, 24V or –48VDC power input Each Black Box LBHXXXA(E)-H/LBHXXXA(E)-P Series is equipped with an internal DC power supply, and has built-in screw terminals for secure attachment of the power input leads. Three DC power models support a range of power input types. The three DC power input terminal block choices are for use with 12VDC, 24VDC or 48VDC power.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Note:The LBHXXXA(E)-H or P models with 24VDC support the Dual Source 24V input option. An external LH1505-CK (SHOWN AT RIGHT…and sold separately, or a customer-supplied equivalent) can be used to input 24VDC power to the LBHXXXA(E)-H or P unit via the jack. This is for 24VDC models only.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 3.6 DC Power Terminals: “+”, “-”, gnd GND: Terminal for “earth” or ground wire connection to the LBHXXXA(E)-H chassis Input Voltage: 12VDC 24VDC -48VDC Alarm Contact Terminal 12VDC (8-15VDC) (12V) (8-15VDC) Input 24VDC (10-36VDC) -48VDC (30-60VDC) (12V or 24V) (10-30VDC) (12V) (8-15VDC) current: 0.8 amp.(12V DC) 0.4 amp max.(24V DC) 0.2 amp max.(-48V DC) Power Consumption:7.0 watts typical, 9.0 watts max.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 3.7 LBHXXXA(E)-H and P Series, DC-powered, 12VDC, 24VDC and -48VDC Installation This section describes the proper connection of the -48VDC leads (or 24VDC, 12VDC leads) to the DC power terminal block on the Black Box LBHXXXA(E)-H Edge Switch (as shown in the Figure). The DC terminal block on the Black Box LBHXXXA(E)-H is located on the left side of the unit and is equipped with three (3) screw-down lead posts.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) the LBHXXXA(E)-H’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) optional; it connects to the Edge Switch chassis. Ensure that each lead is securely tightened from the top, as shown on above picture with arrow. NOTE: Always use a voltmeter to measure the voltage of the incoming power supply and figure out the +ve potential lead or -ve potential lead.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASEFL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer cable distance and higher bandwidths as compared to copper wiring.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shielded) The following procedure describes how to connect a 10BASE-T or 100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted pair cables. 1. 2. 3. 4. 3.8.2 Using standard twisted pair media, insert either end of the cable with a RJ-45 plug into the RJ-45 connector of the port.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the fiber connectors. Save these dust caps for future use. 2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) fiber media to SC connectors, simply snap on the two square male connectors into the SC female jacks of the Fiber connector until it clicks and secures. 3.8.4 Connecting Single-Mode Fiber Optic When using single-mode fiber cable, be sure to use single-mode fiber port connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable (9/125 microns for single-mode, 50/125 or 62.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 3.8.5 Power Budget Calculations for Heavy-Duty LBHXXX, Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget.
Black Box® Heavy Duty Edge Switches Fiber Port Module Speed, Std. Mode Installation and User Guide(07/05) Std. km Wavel Cable X’mitr R’cvr Worst Worst* typical typical* fdx ength Size Output Sens. OPB, distance OPB, distance (hdx) nm dB Km, fdx µm PT , dB PR ,dB dB Km, fdx LBHXXX- 100Mb Multi2 mode (0.4) MST, MSC FX 100Mb Single- 20 LBHXXX- FX mode (0.4) SSC 1310 62.5/125 -20 50/125 -23.5 -31 -31 9.0 5.5 2.5 2.0 14 12 5 4 1310 -31 14 28 17.5 35 2 LBHXXX- 100Mb Multimode (0.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) * Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long distances (i.e., over approx. 400 meters) can be achieved only if the following factors are both applied: • The 100Mb fiber segment must operate in full-duplex (FDX) mode, and • The worst-case OPB of the fiber link must be greater than the fiber cable’s passive Attenuation.
Black Box® Heavy Duty Edge Switches 4.0 Installation and User Guide(07/05) OPERATION 4.1 Dual-Speed Functionality, and Switching The Black Box Heavy-Duty LBHXXX Edge Switches provide SIX switched ports with combination of fiber and copper or copper only. The architecture supports a dual speed switching environment, with standard auto-negotiation capability. The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and speed, and auto-cross for plug polarity. (See Section 4.2).
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Switching, Filtering and Forwarding Each time a packet arrives on one of the switched ports, the decision is taken to either filter or to forward the packet. Packets whose source and destination addresses lie on the same port segment will be filtered, constraining them to one port and relieving the rest of the network from processing them.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing The RJ-45 ports independently support auto-cross (MDI or MDIX) in autonegotiation mode and will work properly with all the other connected devices with RJ45 port whether it supports Auto-negotiation or not (e.g 10Mb Hub) or fixed mode at 10Mb or 100Mb Half/Full Duplex(managed switch).
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 4.3 Dual LEDs, Front-panel and side-panel (Black Box Heavy-Duty LBHXXX) LED Description PWR Illuminates GREEN to indicate power applied. LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device. The Link ports are also represented by LA1, LA2, LA3…LA6.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 4.4 Hardware operated Alarm Contact for monitoring internal power supply The two screws Alarm Contacts feature, standard on Black Box LBHXXXA(E)-H and P, provides Normally Closed (NC) contacts to which the user can attach one sets of status monitoring wires at the green terminal block. When this option is present, the terminal block for Alarm Contacts is part of the Power Input panel in the Black Box LBHXXXs case.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) Useful info about Alarm Contacts in LBHXXXA(E)-H and LBHXXXA(E)-P: 1. Two-position terminal block (1,2) provided next to the DC power input, as shown above. 2. The Alarm Relay contact connected to the two terminals (1,2) is hardware operated. 3. By default it is NC (normally closed). It will open if there is any loss of power to the electronics inside of the unit. 5.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) procedures described in this section or if the LBHXXX Series 10/100 Mb/s Switch is not performing as expected, do not attempt to repair the unit; instead contact your supplier for assistance or contact BLACK BOX Customer Support. 5.1 Before Calling for Assistance 1. If difficulty is encountered when installing or operating the unit, refer back to the Installation Section of the applicable chapter of this manual.
Black Box® Heavy Duty Edge Switches 4. Installation and User Guide(07/05) If the problem is isolated to a network device other than the LBHXXX and LBHXXX Series 10/100 Mb/s switch product, it is recommended that the problem device is replaced with a known good device. Verify whether or not the problem is corrected. If not, go to Step 5 below. If the problem is corrected, the LBHXXX Series Switch and its associated cables are functioning properly. 5.
Black Box® Heavy Duty Edge Switches 2. Installation and User Guide(07/05) An accurate list of BLACK BOX product model(s)involved, with serial number(s). Include the date(s) that you purchased the products from BLACK BOX. 3. It is useful to include other network equipment models and related hardware, including Convenient computers, workstations, terminals and printers; plus, the various network media types being used. 4.
Black Box® Heavy Duty Edge Switches Installation and User Guide(07/05) 5.3 Return Material Authorization (RMA) Procedure Shipping and Packaging Information Should you need to ship the unit back to Black Box Corporation, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original container if available. Units should be wrapped in a "bubble-wrap" plastic sheet or bag for shipping protection. ( You may retain all connectors and this Installation Guide.