B. On the AS/400 command line, type DSPSYSVAL SYS VAL(QAUTORMT),
then press <Enter>. The Auto Configure Remote Controller parameter
should be set to 1=ON.
C. On the AS/400 command line, type DSPSYSVAL SYS VAL(QAUTORMT),
then press <Enter>. The Number of devices to autoconfigure should be
large enough to account for all virtual (APPC) devices on your network. If
you are unsure, you may want to increase this number.
D. On the AS/400 command line, type WRKLIND, then press <Enter>. Enter
a 5 to display, or 2 to change in front of the line that the print server is
attached to. Press <Enter> several times until Autocreate controller is
displayed in the lower section of the menu options. Verify that the
Autocreate controller parameter is set to *Yes.
3. Display the QSYSOPR messages for additional information. On the AS/400
command line, type DSPMSG QSYSOPR, then press <Enter>.
Problem: When resetting the print server while an AnyNet session is (even just
partially) established, the RMT and/or PRT devices generally do not come back
into VARY ON mode.
Resolution: Follow this procedure when resetting the print server in an AnyNet
environment:
1. End the Writer on the AS/400 command line, type endwtr <printer
name>, then press <ENTER>.
2. VARY OFF the PRT and RMT device (wrkdevd <printer name>, 8, 2
(for PRT device) and 2 (for RMT device), <Enter>).
3. End all TCP/IP sessions associated with the Print Server(wrk tcpsts, 3,
scroll to where the Print Server TCP/IP address is displayed (at least once!),
select 4, <Enter>).
4. VARY ON the RMT and then the PRT devices (wrkdvd <printer name>,
8, 1 (for PRT device) and 1 (for RMT device), <Enter>).
5. The RMT and PRT device are now in VARY ON PENDING mode.
6. Reset the print server through the PrintControl utility (R button on first
screen) or by cycling power on the print server.