PORTABLE AIR CONDITIONER INSTRUCTION MANUAL CATALOG NUMBER BPT05WTBA BPT06WTB BPT07WTB Thank you for choosing BLACK+DECKER! PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON. If you have a question or experience a problem with your BLACK+DECKER purchase, go to www.blackanddecker.com/instantanswers If you can’t find the answer or do not have access to the Internet, call 844-299-0879 from 10:30 a.m. to 6:30 p.m. EST Mon. - Fri. to speak with an agent.
CONTENTS SAFETY INFORMATION Important Safety Instructions...........................................................................................................................................3-4 Grounding Instructions.......................................................................................................................................................... 5 LCDI Power Cord and Plug.............................................................................................................
SAFETY INFORMATION DANGER DANGER - Immediate hazards which WILL result in severe personal injury or death WARNING WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death CAUTION CAUTION - Hazards or unsafe practices which COULD result in minor personal injury IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions should be followed, including the following 1.
SAFETY INFORMATION HANDLING ALKALINE BATTERIES WARNING When handling alkaline batteries, basic safety precautions should be followed, including the following 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. Should fluid from the battery accidentally get into your eyes, there is a threat of loss of eyesight, do not rub them. Immediately rinse your eyes with clean tap water and then consult a physician immediately. Do not put the battery in a fire, expose it to heat, dismantle or modify it.
SAFETY INFORMATION GROUNDING INSTRUCTIONS ELECTRICAL REQUIREMENTS In the event of malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. The appliance must be connected to a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
SAFETY INFORMATION LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit. The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. WARNING: Test LCDI before each use. To test the plug: 1.
SAFETY INFORMATION SAFETY GUIDELINES To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. ALWAYS DO THIS • Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditioner where it can fall or be pulled into water or any other liquid. Unplug immediately.
SAFETY INFORMATION OPERATING CONDITION The air conditioner must be operated within the temperature range indicated below: NOTE: · Unit performance may be affected when in use outside of these operating temperatures.
SET UP & USE PARTS & FEATURES Control Panel and Remote Control Sensor Air Outlet Grill Filter Handles Dehumidification Drain Air Exhaust Hose Housing Plug Intake Grill Condensation Drain Castors (4) Air Exhaust Hose Hose Outlet Hose Inlet Locking Screw Window Bracket Drain Hose Drip Pan 3.3 feet long 0.5 inch diameter Remote Control Foam Seal 2 pcs 1 pc.
SET UP & USE SPECIFICATIONS BPT05WTBA Unit dimensions (W x D x H): 16.54” x 12.2” x 27.56” Unit weight approx.: 52.9 lbs. BPT06WTB Unit dimensions (W x D x H): 16.54” x 12.2” x 27.56” Unit weight approx.: 53.9 lbs. BPT07WTB Unit dimensions (W x D x H): 16.54” x 12.2” x 27.56” Unit weight approx.: 56.4 lbs. Electric Requirements: 115V ~ 60Hz INSTALLATION GUIDE LOCATION • The air conditioner should be placed on a firm floor to minimize noise and vibration.
SET UP & USE WINDOW SLIDER KIT INSTALLATION Your window slider kit has been designed to fit most standard “Vertical” and “Horizontal” window applications; however, it may be necessary for you to improvise/modify some aspect of the installation procedures for certain types of window. Minimum and maximum window openings: MAXIMUM : 50” (127 cm) MINIMUM : 20.5” (52 cm) NOTE: · A plastic locking screw is holding the window slider kit together during shipment.
SET UP & USE EXHAUST HOSE INSTALLATION The air exhaust hose and hose inlet must be installed or removed from the portable air conditioner in accordance with the way it is being used: COOL, AUTO, DEHUMIDIFY: Air exhaust hose and hose inlet should be connected to the portable air conditioner. FAN: A ir exhaust hose and hose inlet should be disconnected from the portable air conditioner. Fig. 1 Fig. 2 1. A lign Arrow of hose inlet and hose. Turn either clockwise or counterclockwise to secure (Fig. 1). 2.
SET UP & USE CONTROL PANEL Display Area Selected Mode Indicator Light Mode Selection Button Fan Speed Indicator Light Fan Speed Selection Button ON/OFF Decrease Temp/Time Button Increase Temp/Time Button Pictures are for illustration purpose only. Your model may or may not have all the features. OPERATING FROM THE CONTROL PANEL The Control Panel enables you to manage all the main functions of the appliance, but to fully exploit its potential, you must use the remote control. Fig.
SET UP & USE COOL MODE DEHUMIDIFY MODE Ideal for hot weather when you need to cool the room. To set operation of the appliance Fig. 7 correctly, press the or buttons until the desired temperature is displayed. (See Fig. 7) Ideal for reducing humidity in spring and autumn, during rainy spells or in damp rooms, Fig. 8 etc.
SET UP & USE OPERATING FROM THE REMOTE CONTROL BATTERY INSTALLATION (BATTERIES NOT INCLUDED) (1) Slide open the battery compartment cover. (2) Insert 2 × “AAA”batteries as shown. (3) Slide back the battery cover. CAUTION: Use only AAA or IEC R03 1.5V alkaline batteries. Remove the batteries if the remote is not used for a month or longer. Do not attempt to recharge the batteries. Both batteries should be replaced at the same time. Do not dispose of the batteries in a fire as they man explode.
SET UP & USE REMOTE CONTROL Fan Dehumidify Cool Remote Signal ˚C / ˚F Auto Fan Speed Child Lock Power Button Follow Me Turbo Function Button Increase Fan Speed Timer Sleep Mode Button Timer Button Decrease Sleep Button ˚C / ˚F Selector Fan Speed Button POWER BUTTON: Press to Turn ON or OFF MODE BUTTON: Each time you press the button COOL, DEHUMIDIFY, FAN INCREASE: Increase the temperature setting to 90°F. Also used to set time. DECREASE: Decrease the temperature setting to 64°F.
SET UP & USE LED Display Indicators Cooling mode Fan speed Dehumidify mode Auto speed Fan mode Child lock Timer on Timer off Signal Sleep Display temperature or hours Fahrenheit or Celsius. Turbo Follow me POWER BUTTON • Press to Turn Air Conditioner ON or OFF. • Will show on the remote LED screen when buttons are pressed to show that the remote control is sending a signal to the air conditioner. MODE BUTTON • Press the button to scroll through COOL , DEHUMIDIFY , FAN .
SET UP & USE DEHUMIDIFY Ideal for reducing humidity. • Keep window and door closed for the best dehumidifying effect. • Exhaust hose attachment is not required to reduce humidity, however it is recommended in very humid rooms so the warm air can be exhausted outside. Draining in Dehumidify mode • It is recommended that the dehumidification drain and drain hose be used for continuous drainage. • WATER FULL - When the water level reaches a predetermined level, indicated on the display.
SET UP & USE TO OPERATE TURBO • Press the Function button, TURBO symbol flashes on button again, the TURBO screen then press the function symbol will stop flashing and will illuminate on the LED screen indicating that TURBO is activated. TO CANCEL TURBO • Press the Function button, TURBO symbol flashes on screen then press button again, the TURBO symbol will stop flashing and will the function no longer be illuminated in the LED screen indicating that TURBO function is deactivated.
SET UP & USE TIMER BUTTON • The timer can be used to delay the appliance start-up or shutdown. PROGRAMMING START-UP •W ith the appliance ON select the settings that you would like to program at start-up. Example: COOL Mode, temperature, fan speed. Turn OFF the air conditioner. • Press the button twice, the LED screen will display hours, the symbol will flash symbol and .
SET UP & USE WHEN OPERATING IN COOL MODE • Press the button, and the symbol appears. • Selected temperature will increase by 1°F (1°C) per hour in a 2 hour period. This new temperature will be maintained for the next 6 hours, then the air conditioner will turn off. • When you select the SLEEP function, the screen will reduce the brightness, and the fan speed is low. • The SLEEP function can be canceled at any time during operation by pressing the “Sleep”, “Mode” or “fan speed” button.
SET UP & USE WATER DRAINAGE Draining in Cooling Mode. This air conditioner is equipped with auto water evaporation so the water compartment would not typically fill in cooling mode unless there is high humidity. Water drainage will generally only be required at the end of the season (see START-END OF SEASON OPERATIONS in cooling mode.) NOTE: A s a safety measure to positively prevent water spillage the air conditioner is equipped with a fail safe device if the water tank fills.
SET UP & USE Continuous Draining for Dehumidification Mode. Unplug the unit from the power source. Remove the drain cap located in the back center of the unit. While doing this operation some residual water may spill so have a drip pan (not supplied) to collect the water. Connect the drain hose (supplied) as shown in the diagram. The water can be continuously drained through the hose into a floor drain or bucket. Turn on the unit.
SET UP & USE CLEANING Before cleaning or maintenance, turn the appliance off by pressing the button button on the remote control. Unplug from the on the control panel or electrical outlet. CLEANING THE CABINET You should clean the appliance with a slightly damp cloth then dry with a dry cloth. • Never saturate the air conditioner with water. • Never use petrol, alcohol or solvents to clean the appliance. • Never spray insecticide liquids or similar near the air conditioner.
TROUBLESHOOTING & WARRANTY BEFORE YOU CALL FOR SERVICE IF THE AIR CONDITIONER FAILS TO OPERATE: A) Check to make sure that the air conditioner is plugged in securely. If it is not, remove the plug from the outlet, wait 10 seconds and plug it in again securely. B) C heck for a blown circuit fuse or a tripped main circuit breaker. If these seem to be operating properly, test the outlet with another appliance. WARNING IF NONE OF THE ABOVE SOLVES THE PROBLEM, CONTACT A QUALIFIED TECHNICIAN.
TROUBLESHOOTING & WARRANTY Troubleshoot your problem by using the chart below. If the air conditioner still does not work properly, contact BLACK+DECKER customer service center or the nearest authorized service center. Customers must never troubleshoot internal components. TROUBLE POSSIBLE CAUSE POSSIBLE REMEDY Unit does not start when pressing ON/OFF button A. F T appears in the display window B. Room temperature is lower than set temperature (cooling mode) A. Drain the water A.
TROUBLESHOOTING & WARRANTY LIMITED WARRANTY Any repair, replacement, or warranty service, and all questions about this product should be directed to BLACK+DECKER at 844-299-0879 from the USA or Puerto Rico. BLACK+DECKER warrants to the original purchaser that the product will be free from defects in material, parts and workmanship for the period designated for this product.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.