Indoor Fireplace User Manual

TC30.NGO3.C 100308
8
8. Remove the minimum rate screw located
in the valve. (Fig. #19)
9. Replace the minimum rate screw with the
one provided in the propane conversion
kit supplied with this burner. Ensure that
the screw is fully installed. (Fig. #20)
10) Pull off the rubber cap from the top of
the pressure regulator. (Fig. #21)
11) Press down on the center post and rotate
90°. The center post should stay down.
(Fig. #22). Replace the rubber cap.
12) Fill in the date and the name of the
person who performed the conversion
in the white area on the conversion
label. Peel off the protective backing and
apply the conversion label directly over
the gas speci cations on the rating label.
13) Attach the access panel to the side of
the  rebox with the previously removed
screws. (Fig. #23)
Note: Gasket must be installed with
access panel.
The minimum rate screw is sealed with
an o-ring. Use a thin bladed screwdriver
to back the screw out to the limit of the
threads.
A groove on the screw body will be
visibe just above the valve body. Insert a
thin tool (knife blade or thin screwdriver
blade) into the groove and gently pry
the screw up.
It helps to rotate the screw while
lifting on it.
Fig #19
Fig #20
Fig #21
Minimum
rate screw
Minimum
rate screw
Fig #23
Fig #22
NG
LP