R EADER CONFIGURATION
PRINTED O CTOBER 19, 2010
8
RS-232 Configuration
To configure the reader using RS-232
1 Open a terminal program (RS-232).
2 Establish the following connection settings:
115200 baud rate
1 stop
no parity
no flow control
For RS-232 config port pinouts, see: RS-232 Config Port Pinout (page 1-8).
3 Login using the default password: IPrdr4U.
The password is case sensitive.
4 Type config, and then press Enter at the reader menu.
5 Set the configuration parameters.
See: the VR4100 Configuration Flowchart (page 1-16).
Table 1-1: RS-232 Config Port Pinout
VR4100 (RJ12)
PC Serial Port
DB9 Connector
Signal
Pin 1 Pin 5 Ground
Pin 3 Pin 3 Receive (RX)
Pin 4 Pin 2 Transmit (TX)