User's Manual

12 // USER GUIDE
Loner 900 Light Annunciation Patterns
Loner 900 features audible, tactile and visual indicators for annunciating dierent types of
messages. Please see below for these patterns.
Type Beeper
Vibration
motor
Indicator
light array
Pending alarm Slow alarm
pattern
Single repeating
vibrate
Slow ash
High alarm Fast alarm pattern Double repeating
vibrate
Fast ash
Low battery Single beep once
every 5 minutes
No vibration Single ash
once every
5 minutes
No communication No beeper No vibration Slow double
ash
Ensuring Protection with Loner 900
When safety monitoring is required, perform the following to ensure you are being pro-
tected with Loner 900.
Press the power button to turn on Loner 900.
The Power Button Indicator Light on Loner 900 will blink while establishing a
network connection. The vibration motor vibrates and the beeper annunciates the
power on sequence. Loner 900 will continue to ash the Power Button Indicator
Light while it is establishing a network connection.
2. When the Loner 900 establishes a network connection to the Loner Portal the
Power Button Indicator Light remains on continuously.
3. If you have Fall Detection enabled, wear Loner 900 on your belt at your hip at all
times that you require remote safety monitoring. Perform your work duties as you
normally would. Loner 900 automates remote monitoring of your safety. True Fall
Detection works best when worn on the hip.
4. Power down Loner 900 when remote monitoring of your safety is no longer required.
The Loner 900 logo must face outward, away from your body for optimum GPS and fall