User's Manual

16 // USER GUIDE
If you have not cancelled the alert within 30 seconds, the Fall Detected Alert is sent,
initiating the alert escalation process. Loner 900 will annunciate the high alarm pattern
and will continue until the alert is silenced or the battery is depleted.
Silencing a Fall Detected Alert
1. Press and hold the acknowledge button for 3 seconds.
After three seconds, the pending alarm pattern will be silenced and the Loner 900
will return to regular operation.
If the user cancels a fall detected alert, this does not clear the alert within the Loner
Portal user account. Monitoring personnel are required to address the safety incident.
About Checking In
Loner 900 can be congured in Loner Portal to have you periodically check in. During the
Check-in period, Loner 900 will enter the alarm mode and annunciate the pending low
alarm pattern to indicate a pending Missed Check-in alert. If you do not require assistance,
you have 30 seconds to cancel the alert.
Cancelling a Pending Missed Check-in Alert:
1. Press the acknowledge button for 1 second.
After one second, the pending alarm pattern will be silenced and Loner 900 will
return to regular operation.
If you have not cancelled the alert within 30 seconds, the Missed Check-in alert is sent,
initiating the alert escalation process. Loner 900 will annunciate the high alarm pattern
until the alert is silenced or the battery is depleted.
Cancelling a Missed Check-in Alert
1. Press and hold the acknowledge button for 3 seconds during the pending Missed
Check-in alert.
After three seconds, the alarm pattern will be silenced and Loner 900 will return to
regular operation.
If the user cancels a Missed Check-in Alert, this does not clear the alert within the Loner
Portal user account. Monitoring personnel are required to address the safety incident.
Low Battery Detection
Loner 900 monitors the battery level of the device. If the battery level drops below 20%
of battery capacity, a Low Battery Alert will be sent and Loner 900 will annunciate the low
battery alarm pattern.